10
| PT5300
2.8.6 Ethernet port and PT8643 SNTPv4 Time Server Option
The PT5300 is equipped with a IEEE 802.3 10 BASE-T Ethernet network connection. The Ethernet connection is
fully compatible with 100/1000 BASE-T for both full and half duplex with auto-negotiation and automatic polarity
detection and correction.
Connectors:
1 x RJ45
1 x Female 9 Pin D-SUB
1 x Male 9 Pin D-SUB
•
IPv4
•
Ethernet protocols:
– DHCP Client.
Provides automatic configuration of IP address if a DHCP server is available in the network.
– Telnet Server.
Provides remote control of the PT5300 over the network.
Default Port: 23 (TCP)
– SNTP Server with PT8643 option, also requiring PT8616 GPS Genlock module installed.
Simple Network Time protocol version 4. (Unicast)
Port: 123 (UDP)
– NetFinder.
Provides easy configuration of the PT8643 module. Port: 3040
(UDP)
• RS232 Remote control.
• Changeover control.
2.8.7 Level detectors
All sync pulse generator outputs have built-in level detectors:
Analog Video Signals:
Alarm limits:
<
-3dB or
>
+7dB
SDI:
Measures both current and voltage. When either one is more than 2dB down, the alarm is set.
AES/EBU:
Alarm limits for BNC outputs:
<
0.75V or
>
2.7V
Alarm limits for balanced outputs:
<
2.4V or
>
10V
Alarm limit for Wordclock:
<
1.25V
Response time for detection:
Approx. 2ms.