28
| PT5300
Note:
The genlock timing can only be changed when the genlock type is a signal containing line and field information.
It is not possible to change timing when the reference is 5/10 MHz, Subcarrier frequency or internal.
Note:
When changing genlock signal format, for instance, from PAL to NTSC, the timing parameters may become
invalid: The timing parameter will then be reset to 0 for the input in question.
MENU:GENLOCK, select input
<INTERNAL> SYS TIMING ESC
MENU:GENLOCK, select input
<GPS 625/50> SYS TIMING OK ESC
4.7.4 Menu: GPS Genlock and LTC output
This is the menu for setting the parameters for the GPS Genlock input and the PT8620 LTC output.
Select: GENLOCK
Operation:
• When an input has been configured to a specific type of genlock, this will be shown in the genlock select
input menu.
• Use the and buttons to scroll through the different input options (with attached genlocked types)
• Then move the cursor to OK and press the E button to change the selection (OK is only visible for non-active
selections).
• If no change is desired, move the cursor to ESC and press .
Leaving the function takes you back to the GENLOCK menu.
Select LTC menu.
Settings of the LTC generator:
SUBMNU: LTC, select
SUBMNU: <REFERENCE> TIME
SYNC
• Select the parameter you wish to change, and then press
to enter the parameter submenu for the LTC
generator.