![Dini Argeo 3590EKR Series User Manual Download Page 41](http://html.mh-extra.com/html/dini-argeo/3590ekr-series/3590ekr-series_user-manual_2505697041.webp)
3590EKR, 3590EXP, 3590EXT series indicator
E-AF08_02_13.07_EN_U
41
A.O.
OUT
IN
0.000 kg
A.O.
OUT
IN
10.000 kg
Functioning without hysteresis
(
rL.iSt
“HYSTERESIS” parameter set as
iSt.oFF
)
The operating mode is the same as the previous one, except that just one SETPOINT is entered for each output (“S.1 on”);
for this purpose
the access to the " S.1 oFF " parameter is inhibited.
The entry and specifications are the same for the functioning mode on the gross weight.
15.5.2 EXCLUSIVE FUNCTIONING MODE
By setting the
SEtuP >>
outPut >> r.ModE
parameter on “EXCLuS”, one configures the exclusive use of the outputs:
-
The check is made on all the set outputs starting from the last one (OUT16) to the first one (OUT1).
-
When one of these is enabled the check on the previous ones is excluded.
By selecting this functioning mode and setting the set points in increasing order, one can create outputs activation ranges.
Example:
RELAY
SETPOINT
ACTIVATION RANGE
rL. 1
1.000 kg
From 1.000 to 1.999
rL. 2
2.000 kg
From 2.000 to 2.999
rL. 3
3.000 kg
From 3.000 to 3.999
rL. 4
4.000 kg
From 4.000 onwards.
In this case, if the weight reaches 2.500 kg, ONLY THE “rL. 2” OUTPUT IS ENABLED; if the weight reaches 4.500 kg,
ONLY THE “rL. 4” OUTPUT IS ENABLED.
15.6 DIAGNOSTIC PERIPHERALS
Through function
118
combinable with the desired key (
<< F.KEYS >>
step,
TECH.MAN.REF.
), one enables the diagnostic
peripherals function.
The display shows:
Without expansion board or if the expansion board is not detected
With expansion board
STATUS
DESCRIPTION
ANALOGIC OUTPUT
(A.O)
Analogic output value express in percent.
OUTPUTS
(OUT)
Status output, non active ( ) or active ( ).
INPUTS
(IN)
Status input, non active ( ) or active ( ).
SERIAL COMUNICATIONS
(Tx RX)
The serial communication is active with external device.
WEIGHT
Status of the weight:
-
with unloaded scale;
-
with unstable weight.
SCALE
Number of the active scale (example
,
see section “SELECTION OF SINGLE
SCALE/SUM FUNCTION”) and the relative weight loaded.