![Dini Argeo 3590EKR Series User Manual Download Page 38](http://html.mh-extra.com/html/dini-argeo/3590ekr-series/3590ekr-series_user-manual_2505697038.webp)
3590EKR, 3590EXP, 3590EXT series indicator
E-AF08_02_13.07_EN_U
38
15. OTHER FUNCTIONS
15.1 CALCULATOR
Through function
114
combinable with the desired key (
<< F.KEYS >>
step,
TECH.MAN.REF.
), one enables the calculator
function.
ADDITION
MULTIPLICATION
SUBTRACTION
Procedure:
-
Enter the first value using the numerical keyboard.
-
Press
F1
to add,
F2
to multiply,
F3
to subtract the value.
Terminate the operation:
-
TYPE
the second value and
PRESS ENTER
:
the result will be shown for a few seconds on the LED display.
-
TYPE
the second value and
PRESS TARE
: the result will be shown for a few seconds on the LED display and will be
added (in the addition and multiplication case) or subtracted (in the subtraction case) to the current tare value.
-
PRESS 2nd F
: the NET weight on the scale will be used as a second value and the result will be shown for a few
seconds on the display.
In the end the printing of the “CALCULATOR” will be executed anyway (See section “PRINTOUTS”).
To disable the calculator function, press the C key.
15.2 DISPLAY OF NET WEIGHT WITH SENSITIVITY X 10 (for testing use during calibration)
By pressing at length the
F2
key one will view the net weight with sensitivity times 10
only in single scale weight
visualisation
(press the
C
key to return to the normal visualisation).
NOTES:
-
With approved indicator, the visualisation lasts about 5 seconds, after which it’s disabled.
-
The printout can only be done when the indicator has the standard sensitivity.
15.3 SETTING DATE / TIME
By pressing at length the
F3
key it’s possible to quickly access the setting from the date / time of the instrument:
DAY
ENTER
MONTH
ENTER
YEAR
ENTER
HOUR
ENTER
MINUTES
ENTER
.
15.4 NET
GROSS SWITCH
Only during the display of the sum of the weights, if a tare value has been entered, by pressing in sequence the
2nd F
and
F8
keys, the displayed weight switches back and forth between the net and the gross weight.
NOTES:
With a non approved instrument:
During the weight display conversion it is possible to execute any print function.
With the approved instrument:
The weight conversion remains on the display for only 5 sec.; once this time has passed one returns to the normal
weighing status.