15.5.1.2 SET POINT ON THE NET WEIGHT
By selecting this functioning mode, the output function on the NET weight is enabled; the entry of the SET POINTS and the
specifications are the same as the functioning mode on the gross weight.
15.5.1.3 GROSS WEIGHT AT ZERO
By selecting this functioning mode, the output function on the GROSS weight at 0 is enabled.
15.5.1.4 NET WEIGHT AT ZERO
By selecting this functioning mode, the output function on the NET weight at 0 is enabled.
15.5.1.5 INSTABILITY
By selecting this functioning mode, the output function on the unstable weight is enabled.
15.5.1.6 TOTALISATION
By selecting this functioning mode, the output function is enabled after executing a single weigh or after an output weight (at
the end of an input/output cycle); the output remains enabled until the weigh is restored; in other words, by the passing by
zero of the net weight or by weight instability (see
F.ModE
>>
rEACt
“REACTIVATIONS” parameter of the TECHNICAL
SET-UP,
TECH.MAN.REF.
).
15.5.1.7 SET POINT ON THE PARTIAL TOTAL
By selecting this functioning mode, the output function is enabled on the sum between the NET weight on the scale and the
accumulated net partial total; the entry of the SET POINTS and the specifications are the same as the functioning mode on
the gross weight.
15.5.1.8 SET POINT ON THE GENERAL TOTAL
By selecting this functioning mode, the output function is enabled on the sum between the NET weight on the scale and the
accumulated net general total; the entry of the SET POINTS and the specifications are the same as the functioning mode
on the gross weight.
15.5.1.9 SET POINT ON THE GRAND TOTAL
By selecting this functioning mode, the output function is enabled on the sum between the NET weight on the scale and the
accumulated net grand total; the entry of the SET POINTS and the specifications are the same as the functioning mode on
the gross weight.
15.5.1.10 SETPOINT ON THE NEGATIVE NET WEIGHT
Functioning with hysteresis
(
rL.iSt
“HYSTERESIS” parameter set as
iSt.on
)
By selecting this functioning mode the outputs function on the NEGATIVE NET weight is activated; one enters two
NEGATIVE SET POINTS for each output: a DISABLING one, which, when the NET weight is greater than it, disables the
appropriate output; an ENABLING one, which, when the NET weight is lower or equal than it, it enables the appropriate
output.
The entry and specifications are the same for the functioning mode on the gross weight.
OUT1 STATUS
ENABLED
DISABLED
S1.on S1.Off
NET WEIGHT