>>>SHOW DEVICE
DSSI Bus 0 Node 0 (CLYDE)
-DIA0 (RF73)
DSSI Bus 0 Node 1 (BONNIE)
-DIA1 (RF73)
DSSI Bus 0 Node 5 (TFDR1)
-MIA5 (TF85/TF86)
DSSI Bus 0 Node 6 (*)
DSSI Bus 1 Node 7 (*)
UQSSP Tape Controller 0 (774500)
-MUA0 (TK70)
SCSI Adaptor 0 (761400), SCSI ID 7
-MKA0 (DEC TLZ04 1991(c)DEC)
Ethernet Adapter
-EZA0 (08-00-2B-06-10-42)
Note
Selecting a default boot device other than Ethernet device EZA0 is not
appropriate for diskless and tapeless systems that must boot software
over a network.
For more information about the system booting process, refer to your system
Technical Information
manual.
2.4.2 Booting the System from Console Mode
If the Break Enable/Disable switch is set to enable, your system powers up to
console mode (indicated by the
>>>
prompt) after successfully completing its
self-tests (assuming you did not define a halt action of
REBOOT
or
RESTART_REBOOT
by using the SET HALT console command).
This shows a successful power-up to console mode.
KA6nn-A Vn.n VMB n.n
Performing normal system tests.
66..65..64..63..62..61..60..59..58..57..56..55..54..53..52..51..
50..49..48..47..46..45..44..43..42..41..40..39..38..37..36..35..
34..33..32..31..30..29..28..27..26..25..24..23..22..21..20..19..
18..17..16..15..14..13..12..11..10..09..08..07..06..05..04..03..
Tests completed.
>>>
Operating the System 2–11