This shows the steps for changing the system ID of a specified device from the
factory-supplied ID to 1402193310841 (the system ID for the replacement device
is programmed to match that of the original).
PARAMS>SHOW SYSTEMID
Parameter
Current
Default
Type
Radix
--------- ----------------
----------------
--------
-----
SYSTEMID
0402193310841
0000000000000
Quadword
Hex
B
PARAMS>SET SYSTEMID 1402193310841
PARAMS>SHOW SYSTEMID
Parameter
Current
Default
Type
Radix
--------- ----------------
----------------
--------
-----
SYSTEMID
1402193310841
0000000000000
Quadword
Hex
B
C.3.6 Exiting the DUP Server Utility
After you have completed setting and examining DSSI device parameters, enter
the WRITE command at the
PARAMS>
prompt to save the device parameters you
have changed using the SET command. The changes are recorded to nonvolatile
memory.
If you have changed the allocation class or node name of a device, the DUP
driver utility will ask you to initialize the controller. Answer Yes (Y) to allow the
changes to be recorded and to exit the DUP driver utility.
If you have not changed the allocation class or node name, enter the EXIT
command at the
PARAMS>
prompt to exit the DUP driver utility for the specified
device.
This shows the procedure for saving parameter changes. The controller is
initialized.
PARAMS>WRITE
Changes require controller initialization, ok? [Y/(N)] Y
Stopping DUP server...
>>>
Note
You must repeat the procedures in this appendix for each device for which
you want to change parameters.
Programming Parameters for DSSI Devices C–13