Troubleshooting
4-26
Problem
Possible Cause
Action
Server does not boot
from an internal SCSI
hard disk drive.
Boot device not attached to the
SCSI adapter at the lowest
ROM address.
PCI/EISA scanning order
incorrect.
Bootable CD-ROM drive not
connected to the primary SCSI
adapter.
SCSI boot hard disk drive not
formatted.
SCSI device drivers not
installed or incorrectly installed
on SCSI boot hard disk drive.
Operating system software is
not installed on the SCSI boot
hard disk drive.
Requested partition does not
exist.
SCSI boot hard disk drive at
wrong SCSI address.
SCSI device has failed.
Run the SCU to define the server
boot device.
Refer to the bus scanning
examples in the System Reference
manual.
Connect the CD-ROM to the SCSI
adapter.
Format the SCSI hard disk drive.
CAUTION: Formatting the SCSI
hard disk drive will destroy all the
data on the drive.
Properly install all required SCSI
device drivers.
Install the appropriate operating
system.
Partition the SCSI hard disk drive
and then reload the operating
software.
Set SCSI boot hard disk drive to
lowest “primary” SCSI address.
Replace SCSI device.
SCSI hard disk drive
cannot read or write
information.
Incorrect disk drive jumper
settings.
Loose or incorrectly installed
cables.
SCSI hard disk drive is not
correctly formatted or
partitioned.
Refer to the supplied kit installation
instructions.
Make sure all cables are correctly
installed.
Format and partition as required
using the supplied operating
system.
SBB failure.
Check SBB status LEDs for a
drive failure indication.
Replace the SBB.
Summary of Contents for DIGITAL Server 7100 1200
Page 12: ...Preface viii DEC00421 Typical DIGITAL Server 7100...
Page 88: ...FRU Replacement 5 11 DEC00405 2 Figure 5 5 Unlocking and Removing the Side Panels...
Page 91: ...FRU Replacement 5 14 DEC00697 2 I G H F E D C B A Figure 5 7 Server Front View...
Page 93: ...FRU Replacement 5 16 U T R O N M L J P K S Q DEC00697 3 Figure 5 8 Server Left Side View...
Page 95: ...FRU Replacement 5 18 J L O R P M Q N K DEC01407 2 S Figure 5 9 Server Right Side View...
Page 97: ...FRU Replacement 5 20 B B B F H G C D E A DEC01407 3 Figure 5 10 Server Rear View...
Page 108: ...FRU Replacement 5 31 DEC00692 6 J35 ON Figure 5 15 Main Logic Board Switch Location...
Page 118: ...FRU Replacement 5 41 DEC00978 Figure 5 18 Removing and Replacing the Power Supply...
Page 120: ...FRU Replacement 5 43 DEC00470 2 Figure 5 19 Removing and Replacing the Diskette Drive...
Page 122: ...FRU Replacement 5 45 DEC00470 3 Figure 5 20 Removing and Replacing the CD ROM Drive...
Page 124: ...FRU Replacement 5 47 DE C007 76 Figure 5 21 Removing and Replacing a Cooling Fan...
Page 126: ...FRU Replacement 5 49 DEC 007 77 Figure 5 22 Removing and Replacing the Secondary Cooling Fan 2...
Page 128: ...FRU Replacement 5 51 DEC00778 Figure 5 23 Removing and Replacing the Speaker...
Page 136: ...FRU Replacement 5 59 DEC00779 Figure 5 26 Removing and Replacing a Caster...
Page 142: ...Processor Module Upgrades 6 6 DEC00695 5 Figure 6 1 Removing the Terminator Card...
Page 144: ...Processor Module Upgrades 6 8 DEC00695 3 Figure 6 2 Installing a Processor Module...
Page 146: ...Processor Module Upgrades 6 10 DEC00695 2 Figure 6 3 Removing the Processor Module...
Page 159: ...A 1 8 Service Notes A...
Page 160: ...Service Notes A 2...
Page 161: ...Service Notes A 3...
Page 162: ...Service Notes A 4...