pe_macro(1)
You can still glean some useful information because the front-end program
indicates which message record it was waiting for when it timed out. This
record number is the distance the test was attempting to shift data when the
error occurred. This record number is also the row/column address of the PE
which was attempting the shift.
•
xnetSW
: XNet Shift Southwest Test — This test selects a single PE at a time
and shifts data southwest a distance which is a function of the PEs address.
For each of the 1024 PEs (in a single board system), the test checks the loop
count.
This test is attempting to provoke a parity error. When one occurs, the front-
end program times out waiting for more data from the test and prints the
status of the HSR register which indicates why the test halted.
You can still glean some useful information because the front-end program
indicates which message record it was waiting for when it timed out. This
record number is the distance the test was attempting to shift data when the
error occurred. This record number is also the row/column address of the PE
which was attempting the shift.
•
xnetW
: XNet Shift West Test — This test selects a single PE at a time and
shifts data west a distance which is a function of the PEs address. For each
of the 1024 PEs (in a single board system), the test checks the loop count.
This test is attempting to provoke a parity error. When one occurs, the front-
end program times out waiting for more data from the test and prints the
status of the HSR register which indicates why the test halted.
You can still glean some useful information because the front-end program
indicates which message record it was waiting for when it timed out. This
record number is the distance the test was attempting to shift data when the
error occurred. This record number is also the row/column address of the PE
which was attempting the shift.
Options
-b
Use this option to specify Burn-in test; runs the diagnostic repetitively, reporting
the error count at the end of each pass.
-q
Use this option to specify Quick test; selects a brief version of some of the tests.
-t
Use this option to specify Terse message style; the test prints only the most
essential messages.
Files
Executable file found in directory
$MP_PATH/field/bin
:
pe_macro
See Also
pe_diag, pe_rtbp, pe_scan, pe_xnet
B–58 Data Parallel Unit Reference Pages