Where n is the first slot which contains a module whose MAC address may be
changed.
After you enter the slot number, the following prompt appears:
Enter the MAC address <xx-xx-xx-xx-xx-xx>:
Where <xx-xx-xx-xx-xx-xx> is the current MAC address of the module.
The acceptable formats are as follows:
uu-vv-ww-xx-yy-zz
uu:vv:ww:xx:yy:zz
uuvvwwxxyyzz
where uu, vv, ww, xx, yy and zz are hexadecimal numbers in the range 00 through
FF.
After you respond to the prompt, the new module MAC address is stored.
Connect
Option 18, Connect, allows you to connect to a remote device using the MOP
console carrier. When you choose this option, the following appears:
Sets Enabled
DEChub 90 SNMP Network Management Agent
V1.0
Default Community: public [1]
Default Slot: 1
Name: DECagent 90
IP Address: 255.255.255.255
System Uptime: 12 09:42:45
Connect
Enter the MAC address:
To connect to a device, enter the MAC address of the device.
The acceptable formats are as follows:
uu-vv-ww-xx-yy-zz
uu:vv:ww:xx:yy:zz
uuvvwwxxyyzz
where uu, vv, ww, xx, yy and zz are hexadecimal numbers in the range 00 through
FF.
If a connection is successfully established, you will be connected to that device.
For more information about what to do after a connection is established, refer to
the owner’s manual for the device to which you are connected.
To disconnect the session, press Ctrl/D.
DECagent 90 Management 4–17