Table 5–2 (Cont.) Troubleshooting a DECagent 90 in a DEChub 90 Backplane
If...
Then...
Do this...
If the DECagent 90
does not turn on in
a known good slot,
the DECagent 90 is
defective.
Replace the DECagent 90.
The port 0 network
activity LED is off.
The DECagent 90 or
any other unit in the
DEChub 90 may not be
connected to an active
segment.
Connect a known active segment to
a port (other than port 0) on any
unit in the DEChub 90.
If the DECagent 90 is
connected to a known
active segment and
the port 0 LED is off,
the DECagent 90 is
defective.
Replace the DECagent 90.
5–4 Troubleshooting