No modules remain in this community.
This message appears after you choose the Remove Module option, when you have
removed the last module from the community. You will then be asked whether or
not you want to remove the community as well.
No modules were added to this community.
This message appears after you choose the Add Community option, when you
enter a valid set of community strings and select a hub type, but abort using
Ctrl/C or ESC, without adding any modules. Essentially, you have created an
empty community.
No user input for ’nn’ minutes. Console session terminated ...
This message appears when the console timeout period has expired. This occurs
when there is no user input at the console terminal for the specified period
of time. The console automatically disconnects itself after the timeout period
has expired, and you must restart the console session by entering the console
password. No data is lost when the console is disconnected this way.
Now that the former standalone ’module type’ is in a hub, it must now be
moved to an appropriate slot.
This message appears when you have changed the community size of a standalone
agent or bridge so that it resides in a hub or extended hub. You are prompted for
one of the slots to which the module can be moved.
Password changed.
This message appears when the console password is changed.
Pressing only the RETURN key at the prompt for the new community
string will result in that community string being set to null, effectively
disabling access via that community string. You will not be allowed to
set both community strings to null.
This message appears after you choose the Change Community String option, to
remind you that you cannot set both community strings to null.
Resetting the DECagent 90 will restart the console session.
This message appears after you choose the Reset the Agent option. This system
allows you to abort or continue to reset the agent.
Restoration of factory settings will destroy ALL the information the
DECagent 90 knows about all communities and modules. What will
remain is a community of one, a standalone DECagent 90.
This message appears after you choose the Restore Factory Settings option.
Console Messages B–3