A valid value in each field is 0 to 255 decimal.
Change Community String
Option 6, Change Community String, allows you to change the read-only and
read/write community strings. When you choose this option, the following
appears:
Sets Enabled
DEChub 90 SNMP Network Management Agent
V1.0
Default Community: public [1]
Default Slot: 1
Name: DECagent 90
IP Address: 255.255.255.255
System Uptime: 12 10:42:45
Change Community String
*
*
*
*
*
*
*
*
*
*
NOTICE *
*
*
*
*
*
*
*
*
*
Pressing only the RETURN key at the prompt for the new community
string will result in that community string being set to null,
effectively disabling access via that community string.
You will not be allowed to set both community strings to null.
[1] Read-Only Community String
[2] Read-Write Community String
[3] Trap Community String
Enter your selection:
The following table describes the results of each selection.
If you enter . . .
Then the following prompt appears . . .
1
Enter the read-only community string:
2
Enter the read-write community string:
3
Enter the trap community string:
The maximum community string length is 32 characters.
Note
You may change one of the community strings to null (effectively disabling
access through that community string) by pressing the Return key in
response to the prompt. You cannot set both community strings to null.
DECagent 90 Management 4–7