![Digiplex DGP-319 Installer'S Manual Download Page 9](http://html1.mh-extra.com/html/digiplex/dgp-319/dgp-319_installers-manual_2497784009.webp)
Digiplex Liberator 7
3.1.1 Feature Select Programming
Sections
[001], [002]
and
PGM Programming
are programmed using the Feature Select
Method, where each number from 1 to 8 corresponds to a specific feature or option. Set
these options by turning the number corresponding to the feature ON or OFF. The option
is considered ON when the number appears within the brackets on the LCD keypad or
when the number is illuminated on an LED Keypad. Press the key again to remove or
extinguish the digit, thereby disabling (turning OFF) the option. You turn options ON and
OFF by pressing the corresponding keys on the keypad. Press the keys as many times
as you need to select the desired options and then press
[
ENTER
]
to save.
3.1.2 Module Broadcast
Copy sections [001] to [008] of one Wireless Bus Module to one or more Wireless Bus
Modules. For details see the
Digiplex Reference & Installation Manual
.
3.1.3 WinLoad
With the
WinLoad Security System Management Software,
the control panels, modules
and keypads can be programmed remotely through a modem or on-site at 19,200 baud
with a
306 Adapter
. For details refer to the
Digiplex Reference & Installation Manual
.
3.2 L
OW
B
ATTERY
S
UPERVISION
SECTION
[001]:
OPTION
[1]
When a detector or contact switch’s battery voltage drops below a recommended
level (refer to the transmitter’s Instruction Sheet), its yellow LED will flash and it will
transmit a signal to the Wireless Bus Module indicating that the voltage is low. If this
option is enabled, the Receiver Module will transmit the signal to the control panel.
The control panel will generate a trouble and can transmit a report code to the
monitoring station. For details refer to the
Digiplex Reference & Installation Manual.
From Step 6 in Figure 3.1, page 6, enable or disable the option:
Option
[1]
OFF
= Low Battery Supervision disabled
Option
[1]
ON
= Low Battery Supervision enabled (default)
Summary of Contents for DGP-319
Page 1: ...16 Zone and 16 Remote Wireless Bus Module V1 3 DGP 319 Installer s Guide...
Page 2: ......
Page 4: ...2 Installer s Guide...
Page 7: ...Digiplex Liberator 5 Figure 2 1 Connections for Receiver Module to Control Panel...
Page 24: ...22 Installer s Guide 5 4 REPLACING THE REMOTE CONTROL S BATTERY...