![Digiplex DGP-319 Installer'S Manual Download Page 13](http://html1.mh-extra.com/html/digiplex/dgp-319/dgp-319_installers-manual_2497784013.webp)
Digiplex Liberator 11
These keys represent the hexadecimal values from A to F:
[STAY]
= A
[ARM]
= C
[BYP]
= E
[FORCE]
= B
[DISARM] = D
[MEM]
= F
For installations using the LED Keypads, the hexadecimal values will
illuminate the following LEDs:
(A)
=
[
STAY
]
LED
(C) =
[A1]
LED
(E) =
[
BYP
]
LED
(B)
=
[
FORCE
]
LED
(D) =
[A4]
LED
(F) =
[
MEM
]
LED
3.9 PGM D
EACTIVATION
E
VENT
SECTIONS
[006]
AND
[008]
When a PGM Activation Event occurs, the Receiver Module's on-board PGM will
deactivate when the events programmed in section
[006]
(PGM 1) or section
[008]
(PGM 2) occurs unless PGM Timed Mode is enabled. The PGM Deactivation Event
is programmed the same way as the PGM Activation Event (see section 3.8).
3.10 PGM O
VERRIDE
SECTION
[002]:
OPTIONS
[3]
AND
[7], [4]
AND
[8]
When the PGM Override is enabled in options [3] and/or [7], the Receiver Module
will ignore the PGM Mode, PGM Activation Events, PGM Deactivation Events, and
PGM Timers of the corresponding PGM(s). Options
[4]
and
[8]
control whether each
PGM is activated or deactivated until the PGM Override is disabled.
From Step 6 in Figure 3.1, page 6, enable or disable the options:
Option
[3]
OFF
= PGM 1 Override disabled (default)
Option
[3]
ON
= PGM 1 Override enabled
Option
[4]
OFF
= PGM 1 deactivated (default)
Option
[4]
ON
= PGM 1 activated
Option
[7]
OFF
= PGM 2 Override disabled (default)
Option
[7]
ON
= PGM 2 Override enabled
Option
[8]
OFF
= PGM 2 deactivated (default)
Option
[8]
ON
= PGM 2 activated
Summary of Contents for DGP-319
Page 1: ...16 Zone and 16 Remote Wireless Bus Module V1 3 DGP 319 Installer s Guide...
Page 2: ......
Page 4: ...2 Installer s Guide...
Page 7: ...Digiplex Liberator 5 Figure 2 1 Connections for Receiver Module to Control Panel...
Page 24: ...22 Installer s Guide 5 4 REPLACING THE REMOTE CONTROL S BATTERY...