![Digiplex DGP-319 Installer'S Manual Download Page 11](http://html1.mh-extra.com/html/digiplex/dgp-319/dgp-319_installers-manual_2497784011.webp)
Digiplex Liberator 9
3.5 PGM D
EACTIVATION
M
ODE
SECTION
[002]:
OPTION
[1]
AND
[5]
The Wireless Bus Module has one or two on-board PGMs. Each PGM can be in
Follow Mode
or in
Timed Mode. If the PGM is in Follow Mode, it will deactivate
according to its
PGM Deactivation Event
. If the PGM is in Timed Mode, it will
deactivate according to its
PGM Timer.
However
,
if
PGM Override
is enabled,
Follow Mode and Timed Mode will be ignored.
From Step 6 in Figure 3.1, page 6, enable or disable the options:
Option
[1]
OFF
= PGM 1 in Follow Mode
Option
[1]
ON
= PGM 1 in Timed Mode (default)
Option
[5]
OFF
= PGM 2 in Follow Mode
Option
[5]
ON
= PGM 2 in Timed Mode (default)
Ensure that both the PGM Activation Event and PGM Deactivation Event
are programmed for each PGM for Follow Mode to function properly.
3.6 PGM B
ASE
T
IME
SECTION
[002]:
OPTION
[2]
AND
[6]
These options define the Base Time of the PGM Timers when the PGM is in Timed
Mode.
From Step 6 in Figure 3.1, page 6, enable or disable the options:
Option
[2]
OFF
= PGM 1 Base Time is in seconds (default)
Option
[2]
ON
= PGM 1 Base Time is in minutes
Option
[6]
OFF
= PGM 2 Base Time is in seconds (default)
Option
[6]
ON
= PGM 2 Base Time is in minutes
3.7 PGM T
IMERS
SECTIONS
[003]
AND
[004]
When PGM(s) are in Timed Mode, the values programmed for PGM 1 in section
[003]
and for PGM 2 in section
[004]
are defined as seconds or minutes by the PGM
Base Time. This value can be any decimal from 001 to 255. This defines the time
Summary of Contents for DGP-319