![Digiplex DGP-319 Installer'S Manual Download Page 10](http://html1.mh-extra.com/html/digiplex/dgp-319/dgp-319_installers-manual_2497784010.webp)
8 Installer’s Guide
3.3 C
HECK
-
IN
S
UPERVISION
SECTION
[001]:
OPTIONS
[2]
AND
[3]
The Wireless Bus Module waits for each of its assigned detectors and/or contact
switches to send a status signal within a specified time period to confirm their
presence and functionality. If a device has not sent a signal within the time period,
the Wireless Bus Module will transmit a supervision loss signal to the control panel.
The control panel can generate a trouble, an alarm and/or can transmit a report
code to the monitoring station. For details refer to the
Digiplex Reference &
Installation Manual.
Option
[2]
enables the Check-in Supervision feature and option
[3]
specifies the time period required for the devices to send their signal.
From Step 6 in Figure 3.1, page 6, enable or disable the options:
Option
[2]
OFF
= Check-in Supervision disabled
Option
[2]
ON
= Check-in Supervision enabled (default)
Option
[3]
OFF
= Check-in every 12 hours (default)
Option
[3]
ON
= Check-in every 12 minutes
Ensure that the assigned detectors and/or contact switches are set to the
same time period as the Receiver Module (i.e. if the Receiver Module is set
to Check-in every 12 minutes, the detectors/contact switches must be set to
Check-in every 12 minutes.
3.4 T
AMPER
S
UPERVISION
ON
R
ECEIVER
M
ODULE
SECTION
[001]:
OPTION
[4]
If this option is enabled and the Receiver Module's cover is removed, the on-board
tamper switch will be triggered. When this occurs, the Wireless Bus Module will
transmit a tamper signal to the control panel. The control panel can generate a
trouble, an alarm and/or can transmit a report code to the monitoring station. For
details refer to the
Digiplex Reference & Installation Manual.
From Step 6 in Figure 3.1, page 6, enable or disable the option:
Option
[4]
OFF
= Receiver Module's Tamper Supervision disabled (default)
Option
[4]
ON
= Receiver Module's Tamper Supervision enabled
Summary of Contents for DGP-319
Page 1: ...16 Zone and 16 Remote Wireless Bus Module V1 3 DGP 319 Installer s Guide...
Page 2: ......
Page 4: ...2 Installer s Guide...
Page 7: ...Digiplex Liberator 5 Figure 2 1 Connections for Receiver Module to Control Panel...
Page 24: ...22 Installer s Guide 5 4 REPLACING THE REMOTE CONTROL S BATTERY...