Digiplex DGP-319 Installer'S Manual Download Page 1

16-Zone and 16-Remote Wireless Bus Module 

V1.3

DGP-319

Installer’s Guide

Summary of Contents for DGP-319

Page 1: ...16 Zone and 16 Remote Wireless Bus Module V1 3 DGP 319 Installer s Guide...

Page 2: ......

Page 3: ...8 PGM Activation Event 10 3 9 PGM Deactivation Event 11 3 10 PGM Override 11 3 11 System Reset 12 3 12 Viewing Unknown Serial Numbers 12 4 0 DETECTORS AND CONTACT SWITCHES 13 4 1 Assigning Detectors...

Page 4: ...2 Installer s Guide...

Page 5: ...antennas 15cm H x 16cm L x 3cm W 6in H x 6 5in L x 1 1in W Operating Temperature 0 C to 50 C 32 F to 122 F Operating Humidity 85 PGM Outputs 1 relay an additional PGM Output is available PGM Output cu...

Page 6: ...1 Using a drill or screwdriver punch out the four mounting holes on the back of the plastic case Align the six holes of the printed circuit board with the six pins on the back plastic mounting case an...

Page 7: ...Digiplex Liberator 5 Figure 2 1 Connections for Receiver Module to Control Panel...

Page 8: ...e done through Module Programming Mode in the Digiplex Control Panel from any keypad as shown in Figure 3 1 The sections referred to in Step 5 and the data referred to in Step 6 from Figure 3 1 are ex...

Page 9: ...tails see the Digiplex Reference Installation Manual 3 1 3 WinLoad With the WinLoad Security System Management Software the control panels modules and keypads can be programmed remotely through a mode...

Page 10: ...led Option 2 ON Check in Supervision enabled default Option 3 OFF Check in every 12 hours default Option 3 ON Check in every 12 minutes Ensure that the assigned detectors and or contact switches are s...

Page 11: ...M 2 in Timed Mode default Ensure that both the PGM Activation Event and PGM Deactivation Event are programmed for each PGM for Follow Mode to function properly 3 6 PGM BASE TIME SECTION 002 OPTION 2 A...

Page 12: ...t be programmed for the PGM s in Follow Mode to function properly From Step 5 in Figure 3 1 page 6 PGM 1 enter section 005 PGM 2 enter section 007 Use the PGM Programming Table in the Digiplex Program...

Page 13: ...d the same way as the PGM Activation Event see section 3 8 3 10 PGM OVERRIDE SECTION 002 OPTIONS 3 AND 7 4 AND 8 When the PGM Override is enabled in options 3 and or 7 the Receiver Module will ignore...

Page 14: ...igiplex Control Panel s Reference Installation Manual 3 12 VIEWING UNKNOWN SERIAL NUMBERS SECTION 025 The serial number of a detector contact switch or remote control can be displayed From Step 5 in F...

Page 15: ...216 are all interrelated For example when assigning a detector or contact switch to the Receiver Module 1 The serial number and input number will be assigned in section 101 2 The number of devices wi...

Page 16: ...For example to delete the device assigned in section 109 press the 1 key in section 021 and then press ENTER 4 2 ASSIGNING DETECTORS CONTACT SWITCHES TO ZONES Once the detectors and the contact switch...

Page 17: ...haracters that will appear on the LCD screen below the words Module Data The reading number of characters will appear beside the characters Three characters or less is a very weak signal and the devic...

Page 18: ...serial number will be entered in section 301 2 It will automatically appear in section 030 3 It is assigned to a User Access Code in section 401 4 Its buttons are programmed in section 501 When using...

Page 19: ...e deleted through these sections Use Feature Select Programming see section 3 1 1 to delete a remote control from the system by pressing the corresponding key For example to delete the remote control...

Page 20: ...all the areas assigned to the User Access Code For example you arm with a remote control whose User Access Code is assigned to areas 1 and 3 the control panel will attempt to arm areas 1 and 3 Each s...

Page 21: ...LCD Keypads From Step 5 in Figure 3 1 page 6 1 Enter a section from 501 to 516 depending on the remote control you want to program For example program the buttons for the remote control assigned in se...

Page 22: ...A is programmed to Regular Arm button B is programmed to Disarm and the combination of buttons A B is programmed to activate the PGM s according to PGM Table First Digit 8 Second Digit 0 Feature 4 Th...

Page 23: ...e for Buttons A B Sixth digit enter the choice for Buttons C D BEEP BEEP BEEP Seventh digit enter the choice for Buttons A C Eighth digit enter the choice for Buttons B D BEEP BEEP BEEP BEEP BEEP Conf...

Page 24: ...22 Installer s Guide 5 4 REPLACING THE REMOTE CONTROL S BATTERY...

Page 25: ...be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited...

Page 26: ...Printed in Canada 02 2001 I319EI 04...

Reviews: