F U N C T I O N I N G
EN
DiBO 31
4
Electrical connection
Connection diagram for 7- pole plug:
INDICATION
COLOUR
NAME
L
yellow
left indicator
54G
blue
fog lamp
31
white
mass
R
green
right indicator
58R
brown
right rear light
54
red
brake lights : left &
right
58L
black
left rear ligh
Connection diagram for 13- pole plug:
NUMBER
COLOUR
NAME
1
yellow
left indicator
2
blue
fog lamp
3
white
mass (for poles 1-8)
4
green
right indicator
5
brown
right rear light
6
red
brake lights : left &
right
7
black
left rear light
8
grey
reversing light
9
10
11
12
13
white/black
mass (for poles 9-12)
BREAK TIME
The spraying can be stopped arbitrarily by releasing the handle off the spray
gun. Next acts one must comply, if the spraying pause last longer than ten
minutes (or by abandoning the working area):
• After cleaning at use of the burner, the temperature must be 0°C and you
have to spray during at least an other 5 minutes for cooling down the burner
sufficiently.
• Switch off the machine completely. Put therefore the key contact to position
“0”.
• Release the pressure of the pressure hose by pushing the handle of the spray
gun for a moment.
PUMPS HT
There must be present a pre - pressure (pump) at HT pumps (pumps with high
temperature). The pre - pressure (pump) must provide for sufficient flow of
water to feed the high pressure pump and to occur cavitation. Cavitation is the
phenomenon that in a moving fluid the local pressure is going to be lower than
the vapour pressure of the fluid. Because of this mist bells will arise who can
implode with high power in the pump and could cause damages.
For all these applications at high temperature, it is ABSOLUTELY ESSENTIAL
to feed the pump with positive pressure (at least 3 bar) and with a sufficient
quantity of water.