AC T I VAT I O N
EN
DiBO 33
At the top, the current (actual) temperature is visualized and left the burner
indication.
8
Control Screen 3 (Engine speed setting)
In this screen you can set the desired engine speed. The basic setting at
the start is set at 50%. Move the control stick upwards (increase speed) or
downwards (lower speed) below to set the desired engine speed. Increase/
decrease in steps of 10%. Minimum value 0% - maximum value 100%.
At the top right, the current pressure is visualized.
Pay attention: If the key contact is put into position “ON” , the engine
speed is not adjustable. Start the key contact by before the engine
speed is adjustable!
.
9
Control Screen 4 (Lighting - optional)
In this screen you can set the lighting. Move the control stick upwards (work
light on/off) or downwards (beacon light on/off) to set the desired condition.
Push the control stick to activate, push again to deactivate.
10
Control Screen 5 (transfer pump - optional)
In this screen you can turn on / off the transfer pump.
Move the control stick upwards (turn on) or downwards (turn off).
11
Control Screen 6 (electric motor high pressure pump)
In this screen you can turn on / off the electric motor / high pressure pump.
Move the control stick upwards (turn on) or downwards (turn off). You can restart
only once via the key contact.