3.4.2 HIGH CURRENT
If HIGH CURRENT (> 70 A) is indicated on the G1000 (if installed) or SED (if installed):
1.
ESSENTIAL BUS . . . . . . . . . . . . . . . . . . . . . ON
2.
ENGINE SYSTEM DISPLAY
(if G1000 is installed) . . . . . . . . . . . . . . . . . . select by pressing ENGINE and
SYSTEM softkey on MFD
3.
Circuit breakers . . . . . . . . . . . . . . . . . . . . . . check IN
4.
Ammeter/Voltmeter . . . . . . . . . . . . . . . . . . . monitor
5.
Land on the nearest suitable airfield.