![Dexter Laundry Wn0600ea-13en2x-sskcs-usx Parts & Service Manual Download Page 41](http://html1.mh-extra.com/html/dexter-laundry/wn0600ea-13en2x-sskcs-usx/wn0600ea-13en2x-sskcs-usx_parts-and-service-manual_2490411041.webp)
Part # 8533-097-001 11/16
41
Diagnostic Test Cycle (#31)
There is a diagnostic test cycle to assist in both verifying correct operation and identifying functional problems.
The test cycle is operated by following these steps:
1. Close the washer door
2. Turn the Run/Program Key to the Program Position. The program mode LED (bottom row right side) will
light.
3. Select Test Cycle #31 by using the
Up
and
Down
Arrows on the touch pad. Read the Test Cycle number in the
display.
4. Push the green
Start
button. All lights will be on and “00” will be in the display.
5. Push the
Up
arrow to select the following steps:
6. Injection signal can not be tested for output in this cycle
When the correct step is selected for the component that is to be tested, push the
Start
button to operate
that component. Releasing the
Start
button removes power to the component being tested.
Step 1: Door Locking Solenoid
(Door Sol.# 3 red output light will be lit. Green input #3 and #4 should
be lit.
Step 2: Door Locking Thermoactuator
(Lock Thermo # 2 red output will be lit.)
Step 3: Door Unlocking Thermoactuator
(Unlock Thermo # 1 red output will be lit.)
Step 4: Close Drain Valve
(Drain Valve # 4 red output light will be lit.)
Step 5: Cold Water Valve for the tub
(Cold Tub # 7 red output light will be lit.) The pressure switch low
level setting can be tested at this point. The drain valve is closed and cold water is on for as long as
the START button is pushed When the water level reaches a low level,the water valve will turn off and
no additional cold water can be added. (Green input LED #13 should now be lit).
Step 6: Cold Water Valve for the dispenser
(Cold Dispenser # 6 red output light will be lit.) The pres
sure switch low level setting can also be tested with this step. (See step 5)
Step 7: Hot Water Valve for the tub
(Hot Tub #5 red output light will be lit.) The pressure switch high
level setting can be tested at this point. The drain valve is closed and hot water on for as long as the
START button is pushed. When the water level reaches a high level, the water valve will turn off and
no additional hot water can be added. (Green input led #15 should now be lit.)
Step 8: Hot Water Valve for the dispenser
(Hot Dispenser # 8 red output light will be lit. ) The pres
sure switch high level setting can also be tested with this step. (See step 7)
Step 9: Tumble clockwise
(FWD. #13 red output light will be lit)
Step 10: Tumble counter clockwise
(REV. #14 red output light will be lit)
Step 11: Open Drain Valve
(insures that drain valve is open before spin)
Step 12: Intermediate Extract
(Rev.#13 and Speed1 #15 red output light will be lit.)
Step 13: High Speed Extract
(Rev.#13 and Speed 1#15 and Speed 2 #16 red output light will be lit.)
Warning:
If the washer has had any of the 30 cycles changed from the factory settings,
do not use Step 14 unless you want to reset all 30 cycles back to the factory settings.
Step 14 will delete any changes made to all 30 cycles.
Step 14: Reset all 30 Cycles to Factory Settings
(must push the
Start
Button and hold it, then
push the Up Arrow button to reset to Factory Settings)
To Exit the Test mode, push the red
Stop
button and turn the Run/Program Key back to the Run position.
Summary of Contents for Wn0600ea-13en2x-sskcs-usx
Page 11: ...11 Section 1 Machine Dimensions...
Page 14: ...T 600 Mounting Pad Dimensions Part 8533 097 001 11 16 14...
Page 15: ...T 900 Mounting Pad Dimensions Part 8533 097 001 11 16 15...
Page 16: ...T 1200 Mounting Pad Dimensions Part 8533 097 001 11 16 16...
Page 17: ...Part 8533 097 001 11 16 17 Notes...
Page 18: ...Part 8533 097 001 11 16 18 Notes...
Page 19: ...19 Section 2 Machine Installation Operating Instructions...
Page 26: ...Part 8533 097 001 11 16 26 Notes...
Page 27: ...Part 8533 097 001 11 16 27 Section 3 Machine Programming Instructions...
Page 39: ...Part 8533 097 001 11 16 39 Section 4 Trouble Shooting...
Page 42: ...Part 8533 097 001 11 16 42 WN____ Input Output PCB Board...
Page 43: ...Part 8533 097 001 11 16 43 WN____ Microprocessor PCB Board...
Page 53: ...53 Section 5 Machine Service Procedures...
Page 71: ...Water Level Part 8533 097 001 11 16 71...
Page 76: ...WN0900XA 12EN2X SSKCS USX Schematic Diagram Part 8533 097 001 11 16 76...
Page 77: ...WN1200XA 12EN2X SSKCS USX Schematic Diagram 1 Part 8533 097 001 11 16 77...
Page 78: ...Part 8533 097 001 11 16 78 Notes...
Page 85: ...1 12 2 3 4 5 6 7 8 9 10 13 14 15 16 5 9 13 14 10 9 Part 8533 097 001 11 16 85 11...
Page 95: ...11 7 9 8 10 10 13 12 13 15 14 16 18 8 9 11 8 9 Part 8533 097 001 11 16 95...
Page 101: ...9 15 16 10 11 12 Part 8533 097 001 11 16 101 17 Plunger Switch 1 3 2 4 5 6 7 8 5...
Page 117: ...WN0900XA 12EN2X SSKCS USX Schematic Diagram Part 8533 097 001 11 16 117...
Page 118: ...WN1200XA 12EN2X SSKCS USX Schematic Diagram 1 Part 8533 097 001 11 16 118...
Page 119: ...Part 8533 097 001 11 16 119 Notes...
Page 120: ...Part 8533 097 001 11 16 120 Notes...
Page 121: ...Part 8533 097 001 11 16 121 Section 7 Electric Heated Models...
Page 126: ...Part 8533 097 001 11 16 126 3 4 6 12 4 5 11...
Page 128: ...WN0600EA 13XN Part 8533 097 001 11 16 128...
Page 129: ...WN0900EA 13XN Part 8533 097 001 11 16 129...
Page 130: ...WN1200EA 13XN Part 8533 097 001 11 16 130...
Page 131: ...Part 8533 097 001 11 16 131 Notes...
Page 132: ...Part 8533 097 001 11 16 132 Notes...
Page 133: ...Part 8533 097 001 11 16 133 Section 8 Steam Heated Valve Kit...
Page 139: ...WN0600SA 12XN Part 8533 097 001 11 16 139...
Page 140: ...WN0900SA 12XN Part 8533 097 001 11 16 140...
Page 141: ...WN1200SA 12XN Part 8533 097 001 11 16 141...
Page 142: ...Part 8533 097 001 11 16 142 Notes...
Page 148: ...Part 8533 097 001 11 16 148 WN0600XA 39XN...
Page 149: ...Part 8533 097 001 11 16 149 WN0900XA 39XN...
Page 150: ...Part 8533 097 001 11 16 150 WN1200XA 39XN...
Page 152: ...Part 8533 097 001 11 16 152 50HZ Electric Heated Models 1 2 3 4 2...
Page 154: ...WN0600EA 68XN Part 8533 097 001 11 16 154 Part 8533 053 001 2 09 rev 2...
Page 155: ...WN0900EA 68XN Part 8533 097 001 11 16 155 Part 8533 053 001 2 09 rev 2...
Page 156: ...WN1200EA 68XN Part 8533 097 001 11 16 156 Part 8533 053 001 2 09 rev 2...
Page 157: ...Part 8533 097 001 11 16 157 Section 10 Maintenance...
Page 159: ...Part 8533 097 001 11 16 159 Notes...