![Dexter Laundry Wn0600ea-13en2x-sskcs-usx Parts & Service Manual Download Page 136](http://html1.mh-extra.com/html/dexter-laundry/wn0600ea-13en2x-sskcs-usx/wn0600ea-13en2x-sskcs-usx_parts-and-service-manual_2490411136.webp)
Part # 8533-097-001 11/16
136
Optional Steam Valve Kit
Features
When the numeric temperature value is programmed for any bath, the water valve selection to fill that bath
is
chosen
as
follows:
20 degrees - 35 degrees Centigrade
Cold valve only will be used
40 degrees - 60 degrees Centigrade
Cold and Hot valve will be used
65 degrees - 90 degrees Centigrade
Hot valve only will be used
The temperature control and display are controlled using the temperature control circuit board on the I/O
board, the thermistor sensor in the tub back, and the computor logic board (CPU). The contol voltage is 115
volts (60hz).
Operating Parameters
The programmed temperature will be displayed in Centigrade only.
The steam valve will be activated when the low water level has been reached and the actual water tempera-
ture
is
less
than
the
programmed
temperature.
While the steam valve is engaged, the cylinder will pause 3 minutes between each forward/reverse rota-
tion. The cylinder will resume normal operation once the water bath temperature is within 5 degrees of the
programmed temperature.
Cycle countdown time display will stop while valve is engaged.
During the cycle, if the water bath temperature drops 3 degrees below the programmed temperature, the
steam valve will engage to maintain the water temprature.
The actual water temperature will display by pressing the Start and Down arrows simultaneously. The tem-
perature light will be on whenever the temperature is being displayed. The temprature light will continue to
be displayed until the Start button is pushed again, changing the display over to time remaining.
The control can be programmed to maintain any temperature between 20 degrees and 90 degrees. The
programming
is
in
5
degree
increments.
Any bath that has a programmed spin cycle will go through a short cool down bath before spinning if the
actual bath temperature at the time of draining is above 65 degrees . This bath consists of filling tub to low
level with WARM water while tumbling and then draining. This will continue until bath temperature is below
65 degrees.
Summary of Contents for Wn0600ea-13en2x-sskcs-usx
Page 11: ...11 Section 1 Machine Dimensions...
Page 14: ...T 600 Mounting Pad Dimensions Part 8533 097 001 11 16 14...
Page 15: ...T 900 Mounting Pad Dimensions Part 8533 097 001 11 16 15...
Page 16: ...T 1200 Mounting Pad Dimensions Part 8533 097 001 11 16 16...
Page 17: ...Part 8533 097 001 11 16 17 Notes...
Page 18: ...Part 8533 097 001 11 16 18 Notes...
Page 19: ...19 Section 2 Machine Installation Operating Instructions...
Page 26: ...Part 8533 097 001 11 16 26 Notes...
Page 27: ...Part 8533 097 001 11 16 27 Section 3 Machine Programming Instructions...
Page 39: ...Part 8533 097 001 11 16 39 Section 4 Trouble Shooting...
Page 42: ...Part 8533 097 001 11 16 42 WN____ Input Output PCB Board...
Page 43: ...Part 8533 097 001 11 16 43 WN____ Microprocessor PCB Board...
Page 53: ...53 Section 5 Machine Service Procedures...
Page 71: ...Water Level Part 8533 097 001 11 16 71...
Page 76: ...WN0900XA 12EN2X SSKCS USX Schematic Diagram Part 8533 097 001 11 16 76...
Page 77: ...WN1200XA 12EN2X SSKCS USX Schematic Diagram 1 Part 8533 097 001 11 16 77...
Page 78: ...Part 8533 097 001 11 16 78 Notes...
Page 85: ...1 12 2 3 4 5 6 7 8 9 10 13 14 15 16 5 9 13 14 10 9 Part 8533 097 001 11 16 85 11...
Page 95: ...11 7 9 8 10 10 13 12 13 15 14 16 18 8 9 11 8 9 Part 8533 097 001 11 16 95...
Page 101: ...9 15 16 10 11 12 Part 8533 097 001 11 16 101 17 Plunger Switch 1 3 2 4 5 6 7 8 5...
Page 117: ...WN0900XA 12EN2X SSKCS USX Schematic Diagram Part 8533 097 001 11 16 117...
Page 118: ...WN1200XA 12EN2X SSKCS USX Schematic Diagram 1 Part 8533 097 001 11 16 118...
Page 119: ...Part 8533 097 001 11 16 119 Notes...
Page 120: ...Part 8533 097 001 11 16 120 Notes...
Page 121: ...Part 8533 097 001 11 16 121 Section 7 Electric Heated Models...
Page 126: ...Part 8533 097 001 11 16 126 3 4 6 12 4 5 11...
Page 128: ...WN0600EA 13XN Part 8533 097 001 11 16 128...
Page 129: ...WN0900EA 13XN Part 8533 097 001 11 16 129...
Page 130: ...WN1200EA 13XN Part 8533 097 001 11 16 130...
Page 131: ...Part 8533 097 001 11 16 131 Notes...
Page 132: ...Part 8533 097 001 11 16 132 Notes...
Page 133: ...Part 8533 097 001 11 16 133 Section 8 Steam Heated Valve Kit...
Page 139: ...WN0600SA 12XN Part 8533 097 001 11 16 139...
Page 140: ...WN0900SA 12XN Part 8533 097 001 11 16 140...
Page 141: ...WN1200SA 12XN Part 8533 097 001 11 16 141...
Page 142: ...Part 8533 097 001 11 16 142 Notes...
Page 148: ...Part 8533 097 001 11 16 148 WN0600XA 39XN...
Page 149: ...Part 8533 097 001 11 16 149 WN0900XA 39XN...
Page 150: ...Part 8533 097 001 11 16 150 WN1200XA 39XN...
Page 152: ...Part 8533 097 001 11 16 152 50HZ Electric Heated Models 1 2 3 4 2...
Page 154: ...WN0600EA 68XN Part 8533 097 001 11 16 154 Part 8533 053 001 2 09 rev 2...
Page 155: ...WN0900EA 68XN Part 8533 097 001 11 16 155 Part 8533 053 001 2 09 rev 2...
Page 156: ...WN1200EA 68XN Part 8533 097 001 11 16 156 Part 8533 053 001 2 09 rev 2...
Page 157: ...Part 8533 097 001 11 16 157 Section 10 Maintenance...
Page 159: ...Part 8533 097 001 11 16 159 Notes...