Page 1: ...8533 097 001 11 16 OPL 30 Cycle 100G PARTS SERVICE MANUAL Including Electric Steam Heated Models 50Hz 60Hz...

Page 2: ...RISK OF DAMAGE OR INJURY refer to accompanying documents follow all steps or procedures as instructed This is the electrical hazard symbol It indicates that there are DANGEROUS HIGH VOLTAGES PRESENT i...

Page 3: ...e Prohibited Do not step or stand on this equipment Prohibited Do not operate without all guards and covers in place Prohibited Do not operate without all guards and covers in place Prohibited Do not...

Page 4: ...y This is the user caution symbol It indicates a condition where damage to the equipment re sulting in injury to the operator could occur if operational procedures are not followed TO REDUCE THE RISK...

Page 5: ...d in the installation and op eration instructions unless qualified Do not install washers in an explosive atmosphere Care must be stressed with all foundation work to ensure a stable unit installation...

Page 6: ...ry or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety A washer s...

Page 7: ...Prohibited Do not step or stand on this equip ment Prohibited Do not operate without all guards and covers in place Prohibited Do not operate without all guards and covers in place Prohibited Do not...

Page 8: ...mentation be fore operating or maintaining equipment Mandatory Disconnect power before servicing equipment Mandatory Lock out and tag out before servicing this equipment Mandatory Disconnect water sup...

Page 9: ...l Removal 54 Drain Valve Access 54 Drain Valve Cleaning 54 Detergent Dispenser 54 Vacuum Breaker Air Gap 55 Water Valves 55 Door Lock Assembly Operation 55 Adjustment of the Door Lock Assembly 55 56 A...

Page 10: ...ure Switch 69 70 Power Connection Terminal Block 71 Delta Variable Frequency Drive 71 Delta VFD Motor Leads 71 Delta VFD Dynamic Braking Resistors 71 Delta VFD Cooling Fan 71 Maxium Spin Speed Adjustm...

Page 11: ...11 Section 1 Machine Dimensions...

Page 12: ...9999 669 003 Wn1200ea 13en2x sskcs usx 60 3ph 208 240v Heated Electric 100 Model hz Phase Voltage Heat Option G s 9999 662 002 Wn0600xa 39xn2x sskcs vrx 50 1ph 230 240v 100 9999 662 004 Wn0600ea 68xn...

Page 13: ...Dimensions 8514 244 001 REV PR page 6 Figure 1 4 T 900 950 Industrial Washer Mounting Diagram NOTE Top water valves shown in Figure 1 4 are only on T 950 model Figure 1 4 T 1200 Industrial Washer Mou...

Page 14: ...T 600 Mounting Pad Dimensions Part 8533 097 001 11 16 14...

Page 15: ...T 900 Mounting Pad Dimensions Part 8533 097 001 11 16 15...

Page 16: ...T 1200 Mounting Pad Dimensions Part 8533 097 001 11 16 16...

Page 17: ...Part 8533 097 001 11 16 17 Notes...

Page 18: ...Part 8533 097 001 11 16 18 Notes...

Page 19: ...19 Section 2 Machine Installation Operating Instructions...

Page 20: ...y Plumbing Water supply hoses are furnished with each machine The threaded connections on the hoses are standard garden hose type thread Separate hot and cold water lines with shut off valves or fauce...

Page 21: ...n 216 and 240 volts NOTE L1 on the transformer must be set at proper tap for proper operation Electrical Connections Electrical power connections are made to the small terminal block located in the re...

Page 22: ...a separate terminal block for connection of the external injection signals For the injection sources program codes 0 through 6 are as shown in the table below Injection signal will trigger a 120 volt...

Page 23: ...the display If the cycle was stopped in the middle depressing the START will begin the cycle from the point at which the cycle was stopped SCROLL UP ARROW BLUE Push button Depress momentarily depress...

Page 24: ...und opening in the top of the machine Location is illustrated on the black cover on the top of the machine NOTE Any additional washing compounds may be added at the appropriate time by pouring into th...

Page 25: ...hown in the table below The Scroll Up Scroll Down buttons are used to change the settings Bath Setting Limits Cycle Time 0 to 30 minutes 1 minute increments The Cycle time tumble settings are 0 minute...

Page 26: ...Part 8533 097 001 11 16 26 Notes...

Page 27: ...Part 8533 097 001 11 16 27 Section 3 Machine Programming Instructions...

Page 28: ...ROLL UP SCROLL DOWN buttons to change the tumble time in 1 minute increments to the desired value then continue to the next instruction Settings range is from 0 minutes to 30 minutes except for the Fi...

Page 29: ...is complete The next sequential cycle segment LED lights unless the segment edited above was the Final Rinse Extract segment If the Final Rinse Extract segment is edited after step eleven the cycle pr...

Page 30: ...th Care 13 Sheets and Pillowcases 14 Towels 15 Diapers and Pads 16 Personals 17 Delicate Food Beverage 18 White Cotton Blend Table Linen 19 Colored Cotton Blend Table Linen 20 White 100 Polyester Tabl...

Page 31: ...rch Cycle Water Water Inject Spin Segment Time Temp Level Source Time Flush Pre wash Wash 12 HH LO Detergent Bleach Rinse 1 2 CH HI Rinse 2 2 CH HI Rinse 3 2 CH HI Rinse 4 Rinse 5 Final 7 CH LO Starch...

Page 32: ...7 HH LO Bleach Rinse 1 2 CH HI 1 Rinse 2 2 CH HI Rinse 3 Rinse 4 Rinse 5 Final 4 CH LO Sour Soft 5 CYCLE 6 Hotel Motel Color Sheets Cycle Water Water Inject Spin Segment Time Temp Level Source Time F...

Page 33: ...s Cycle Water Water Inject Spin Segment Time Temp Level Source Time Flush 2 CH HI Pre wash Wash 7 HH LO Detergent Rinse 1 7 HH LO Bleach Rinse 2 2 CH HI 1 Rinse 3 2 CH HI Rinse 4 Rinse 5 Final 4 CH LO...

Page 34: ...O Bleach Rinse 4 3 HH HI 1 Rinse 5 Final 3 CH HI 4 CYCLE 13 Health Care Sheets and Pillowcases Cycle Water Water Inject Spin Segment Time Temp Level Source Time Flush 3 CH HI Pre wash 2 CH HI Wash 7 H...

Page 35: ...1 2 HH HI Rinse 2 2 CH HI Rinse 3 2 CH HI Rinse 4 Rinse 5 Final 4 CH LO Sour Soft 4 CYCLE 17 Health Care Delicate Cycle Water Water Inject Spin Segment Time Temp Level Source Time Flush 2 CH HI Pre w...

Page 36: ...HH LO Bleach Rinse 3 2 CH HI 1 Rinse 4 2 CH HI Rinse 5 Final 4 CH LO Sour Starch 4 CYCLE 21 Food and Beverage Colored 100 Polyester Linen Cycle Water Water Inject Spin Segment Time Temp Level Source T...

Page 37: ...2 2 HH HI 1 Rinse 3 2 CH HI Rinse 4 2 CH HI Rinse 5 Final 4 CH LO Sour Starch 4 CYCLE 25 Food and Beverage White Colors 100 Polyester Linen Cycle Water Water Inject Spin Segment Time Temp Level Sourc...

Page 38: ...leach Rinse 1 2 HH HI Rinse 2 2 CH HI 1 Rinse 3 2 CH HI Rinse 4 Rinse 5 Final 4 CH LO Sour Soft 3 CYCLE 29 Other Oxygen Bleach Terry No Iron Cycle Water Water Inject Spin Segment Time Temp Level Sourc...

Page 39: ...Part 8533 097 001 11 16 39 Section 4 Trouble Shooting...

Page 40: ...ile the tumbler is decelerating If a temperature PCB is installed in the I O PCB and the temperature programmed from 20 to 90 Celsius advancing will turn off the heater relay or steam valve immediatel...

Page 41: ...will turn off and no additional cold water can be added Green input LED 13 should now be lit Step 6 Cold Water Valve for the dispenser Cold Dispenser 6 red output light will be lit The pres sure switc...

Page 42: ...Part 8533 097 001 11 16 42 WN____ Input Output PCB Board...

Page 43: ...Part 8533 097 001 11 16 43 WN____ Microprocessor PCB Board...

Page 44: ...c power is at solenoid after start button is pushed Machine starts then stops Door Switch Ass y I O PCB must have green input lights DOOR LOCK 3 DOOR CLOSED 4 TUB EMPTY 14 RUN KEY 2 START 6 WILL BE ON...

Page 45: ...ay change Ribbon Cables between CPU and input output board If red door lock solenoid output light on input output board is illuminated check that 120VAC is going from the input output board to the doo...

Page 46: ...t Out put Board Check Input Output PCB for alternating or Input Output PCB red output lights for forward 13 and reverse 14 If no red output lights illuminated check single red light on CPU board Singl...

Page 47: ...ors 1 Disconnect power to washer for 2 minutes to reset motor drive 2 Check incoming power to washer for correct voltage Line volt age out of the specified operating range will cause the drive to faul...

Page 48: ...ables between CPU and input output PCB Check with factory for latest testing proce dures for I O PCB If red intermediate and high extract output lights on input output board are illuminated check to i...

Page 49: ...PU board Single red light should be illu minated If light is flashing or not on remove power from washer for 2 minutes to reset board Reapply power to washer and check red CPU light If on solid CPU ok...

Page 50: ...tests okay change Ribbon Cables between CPU and Input Output PCB Check with factory for latest testing procedures for I O PCB If still not corrected change Input Output PCB Water comes in but level do...

Page 51: ...it is no longer powered The Drain Valve is powered closed with 120VAC from the Input Output PCB red output light 4 on Input Output PCB will be lit on the brown yellow wire Fill All Wash Rinse Empty Ba...

Page 52: ...to the designated terminals on the back of the washer All Chemical injections signals are delayed until 10 seconds after the tub starts to fill with water All signals are 10 seconds in duration Interm...

Page 53: ...53 Section 5 Machine Service Procedures...

Page 54: ...e drain valve motor It is mounted under the washer tub on the left side It is spring loaded open If power is interrupted to the washer the motor releases the sealing ball allowing the drive spring to...

Page 55: ...that it can t rotate to unlock The second job is to close the two piggyback lock sensing switches These switches control power to all of the controls If the door unlocks for any reason these two switc...

Page 56: ...Check that lock pawl arm swings to cam lobe to lock position Step 6 The lock stacked switches piggyback must be adjusted as door lock solonoid pulls up on door rod and locking pawl is now blocking do...

Page 57: ...or pressure can be evaluated by inserting a dollar bill in several positions and tugging on it See Parts Section for kit to increase door sealing pressure Loading Door Removal Step 1 Support door to p...

Page 58: ...pulling the gasket in place Step 3 The front lip of the door gasket should be checked for proper seating Front Control Panel Name Plate Decal The name plate on washer front is adhesive backed Front Co...

Page 59: ...not overtighten Step 7 Remove clamp and soap dispenser hose where it attaches to the tub inlet Disconnect the door lock wires from all switches and the door lock solenoid Step 8 Disconnect pull rod b...

Page 60: ...e cycle making it extend and block the door locking gear motor This keeps the door locked for approximately two minutes after a power failure occurs The lock thermoactuator does not delay the door ope...

Page 61: ...l Step 1 Remove the top and back panel as described Step 2 Move the rear channel that the water valves mount to forward by removing the five mounting screws Step 3 Remove the drive belt Step 4 Remove...

Page 62: ...n place inside the pulley Step 2 The shoulder inside the pulley that holds the tolerance ring should face the back of the washer when installed correctly Step 3 Use a stack of flat washers and a longe...

Page 63: ...e unlikely event that the metal ring that mounts these sealing rings were to be damaged or moved a new one would need to be pressed on The ring must be pushed against the stop on the shaft Before inst...

Page 64: ...y the tub front loose Step 8 Remove the rear access panel Step 9 Remove the drive belts Step 10 Remove drive pulley Remove 3 retaining screws Insert 3 3 8 16 x 2 screws into the threaded removal holes...

Page 65: ...Ring Mating Ring Seals Mating Ring Mounting Ring NOTE If the tub back water seal mating ring has been moved it must be cleaned and re sealed T 900 and T 1200 WATER SEALS Replacement Step 1 Remove cyl...

Page 66: ...ation of the outer tub front Step 4 Clean the silicone rubber off the tub front and the outer tub Step 5 Install new bead of silicone rubber on tub front Step 6 Install tub front Step 6A Align hole in...

Page 67: ...l door front panel lower service panel and top T 600 Bolt Torque Chart Bolt Size Where Used Torque 1 2 x 1 1 4 bolt Tub End of Bearing Hsing 9545 017 009 70 110 ft lbs 5 8 x 1 1 2 bolt Tub End of Bear...

Page 68: ...but does not include the motor To reset the circuit breaker just push in the button If you have a fuse then remove fuseholder and fuse and replace with a 1 1 2 amp fast blow type fuse PCB Transformer...

Page 69: ...e water level Before making any adjustments of the pressure switch drain the tub and blow the hose clear of possible water bubbles which can cause erratic pressure switch operation With no load the wa...

Page 70: ...6ZLWFK 6ZLWFK 6ZLWFK 6ZLWFK IILFLHQW ODVVLF RZ HYHO LJK HYHO 7 7 7 7 7 6 7 7 7 7 7 7 7 DFWRU 6HWWLQJV 9HQGHG 2Q 3UHPLVH 0RGHO Part 8533 097 001 11 16 70...

Page 71: ...Water Level Part 8533 097 001 11 16 71...

Page 72: ...e current or voltage reading is not possible Although an accurate current reading is not possible a balanced current reading should be present while the motor is running Delta VFD Dynamic Braking Resi...

Page 73: ...extract spin speed for all wash cycles To make this adjustment a jumper wire must either be installed or removed on the Variable Frequency Drive VFD depending on the washer model and desired speed Thi...

Page 74: ...45 2 71 60lb 80lb Series Washer Resistance Motor Winding Wire Minimum Maximum 60lb 1ph or 3ph 60hzMain wash spin T1 T2 2 4 2 8 9376 308 001 Marathon T2 T3 2 4 2 8 T1 T3 2 4 2 8 Drive Motor Inverter Ty...

Page 75: ...WN0600XA 12EN2X SSKCS USX Schematic Diagram OPL Maxi Load 40lb Wiring Schematic 12 Part 8533 097 001 11 16 75...

Page 76: ...WN0900XA 12EN2X SSKCS USX Schematic Diagram Part 8533 097 001 11 16 76...

Page 77: ...WN1200XA 12EN2X SSKCS USX Schematic Diagram 1 Part 8533 097 001 11 16 77...

Page 78: ...Part 8533 097 001 11 16 78 Notes...

Page 79: ...SSKCS USX 60 3ph 208 240v Heated Electric 100 Model HZ Phase Voltage Heat Option G s 9999 662 002 WN0600XA 39XN2X SSKCS VRX 50 1ph 230 240v 100 9999 662 004 WN0600EA 68XN2X SSKCS VRX 50 3ph 400v Heate...

Page 80: ...6 003 8641 586 003 Sealing compound 8538 151 002 8538 151 002 8538 151 002 Flow Restrictors in dispenser 9475 002 002 9475 002 002 2 Flow Restrictors in dispenser 9475 002 003 3 Special Tool for adjus...

Page 81: ...001 1 Wiring Assembly Diode 8220 001 442 8220 001 442 8220 001 442 1 Wiring Assembly Red 8 8220 108 009 1 Wiring Assembly Wht Brn 8 8220 108 007 1 Wire Jumper White Red 8220 090 001 8220 090 001 8220...

Page 82: ...02 614 004 1 Label Fusing Installation 8502 619 004 8502 619 003 8502 619 003 1 Label Quality 8511 001 002 8511 001 002 8511 001 002 1 1 Label Warning Risk of Injury Black 8507 759 001 8507 759 001 85...

Page 83: ...640 412 005 7 Nut Hexelasticstop 4 40 8640 424 002 2 2 Membran Switch assy Black 9801 061 002 9801 061 002 9801 061 002 Plate Membrane switch Assy 9452 637 001 9452 637 001 9452 637 001 1 3 PCB Displa...

Page 84: ...001 8641 585 001 8641 585 001 2 Spring Nut 8640 399 008 8640 399 008 8640 399 008 5 Band Edge Protector Trim 9578 092 005 9578 092 002 9578 092 002 1 6 Bumper Loading Door 9051 055 001 9051 055 001 90...

Page 85: ...1 12 2 3 4 5 6 7 8 9 10 13 14 15 16 5 9 13 14 10 9 Part 8533 097 001 11 16 85 11...

Page 86: ...Part 8533 097 001 11 16 86 Cabinet and Front Panel Group Part by Model Front Soap Dish 7 8 1 2 6 4 5 3 Tub Front Here 9 10 20 19 18 17 16 15 14 13 12 11 18 11 17 Gasket and Soap Dish Here...

Page 87: ...Locator 9545 008 023 9545 008 023 9545 008 023 1 8 Plastic Sleeve Locator 9355 001 001 9355 001 001 9355 001 001 1 Catch Top Panel 9086 017 001 9086 017 001 9086 017 001 2 Lock Top w Key 8650 012 003...

Page 88: ...2 5 Clamp Worm 316SS 1 5 8654 117 019 2 6 Strap Bracket Motor Tension 9029 206 001 1 Nut Strap to Motor 10 32 UNF 8640 413 002 1 Washer 10 8641 581 006 1 7 Spring Belt Tension 9534 319 002 1 8 Pulley...

Page 89: ...1 Hose Vacuum Breaker to tub 9242 461 001 1 Hose Vacume Breaker to Injector 9242 461 001 1 Clamps 8654 117 014 1 16 Injector Assembly Soap 9883 009 001 1 Hose Injector to Tub Back 9242 462 001 1 Clamp...

Page 90: ...Spring Tension 9099 012 003 9099 012 004 1 8 Spring Belt Tension 9534 151 000 9534 151 000 1 9 Pulley Driven 9453 176 005 9453 176 005 1 10 Bolt 3 8 16 x 2 9545 029 011 9545 029 011 3 11 Washer 3 8 86...

Page 91: ...42 449 003 1 Clamp Hose Over Flow 8654 117 008 8654 117 008 2 18 Drain Valve 9379 202 001 9379 202 001 1 Hose Drain Valve to Tube 9242 457 001 9242 457 001 1 Clamp 8654 117 014 8654 117 014 2 19 Drain...

Page 92: ...3 067 001 9053 067 001 9053 067 001 1 16 Bushing Insulated 1 9053 067 004 9053 067 004 9053 067 004 1 Cover Terminal Block 9074 267 001 9074 267 001 9074 267 001 1 Screw 10Bx1 2 9545 008 026 9545 008...

Page 93: ...001 9029 077 001 9029 077 001 1 36 Screw 10Bx1 2 9545 008 026 9545 008 026 9545 008 026 4 37 Clamp Vacuum Breaker End 8654 117 014 8654 117 014 8654 117 014 1 38 Hose Vacuum Breaker to Tub Injection...

Page 94: ...140 006 1 10 Ring Seal Mounting 9950 048 001 1 11 Back Assy Tub 9962 013 001 1 12 Bolt 7 16 14x1 1 2 Tub end of bearing housing 9545 059 003 6 12 Nut 5 8 8640 425 001 6 13 Support Arm Assy Bearing Ho...

Page 95: ...11 7 9 8 10 10 13 12 13 15 14 16 18 8 9 11 8 9 Part 8533 097 001 11 16 95...

Page 96: ...9545 059 004 6 13 Washer Flat 8641 581 034 8641 581 034 6 14 Screw Hex Cap 3 4 10 x 3 Bearing Housing to Frame 9545 057 002 9545 057 002 6 15 Washers Spherical 3 4 Male half Bearing Housing to Frame 8...

Page 97: ...74 011 001 9974 011 002 1 Gasket Tub Front 9206 421 002 9206 421 002 1 Ring Assy Tub Mtg Front Clamp 9950 055 001 9950 055 001 1 Bolt Top Front Ring 3 8 16 x 3 9545 029 009 9545 029 009 1 Nut 3 8 16 8...

Page 98: ...x 10 32 x 1 9545 012 020 1 11 Nut Elastic Stop 10 32 8640 413 004 2 12 Spring Return 9534 364 001 2 13 Pin Guide 9451 193 001 1 1 Key Description All Models QTY 14 Ring Retaining 9487 200 005 1 15 Was...

Page 99: ...4 137 015 1 7 Spring Extension 9534 350 001 9534 350 001 9534 350 001 1 6 Thermoactuator Door Lock Relay 120v 9586 001 001 9586 001 001 9586 001 001 2 5 Arm Door Lock 9001 063 001 9001 063 001 9001 06...

Page 100: ...tch 8220 063 028 8220 063 028 2 5 Switch Door Hinge Close Plunger 9539 492 001 9539 492 001 1 6 Top Door Hinge Leaf No pin 9845 006 001 9845 006 001 1 7 Bottom Door Hinge Leaf 9845 007 001 9845 007 00...

Page 101: ...9 15 16 10 11 12 Part 8533 097 001 11 16 101 17 Plunger Switch 1 3 2 4 5 6 7 8 5...

Page 102: ...Door Handle groove 9451 181 006 9451 181 006 9451 181 006 1 11 Thrd Form Screw Door Mtg 5 16 x 5 8 9545 056 002 9545 056 002 9545 056 002 3 Lockwasher 5 16 Ext hinge mtg 8641 582 009 8641 582 009 8641...

Page 103: ...94 001 8639 994 001 3 6 Spring Drive 9534 339 001 9534 339 001 9534 339 001 1 7 Screw 9545 054 001 9545 054 001 9545 054 001 2 8 Screw 9545 054 002 9545 054 002 9545 054 002 1 9 Seal V Packer 9532 134...

Page 104: ...ve 11 9 8 10 1 6 5 3 2 4 Key Description T 600 T 900 T 1200 QTY Valve Water Inlet includes 1 thru 6 9379 183 012 9379 183 012 9379 183 012 2 1 Screen Inlet end of valve 9555 056 001 9555 056 001 9555...

Page 105: ...ler 9379 194 001 9379 194 001 2 1 Valve Water Body Complete no coil 9379 194 002 9379 194 002 2 2 Diaphragm Mueller 9118 055 001 9118 055 001 1 3 Filter Mueller 9183 046 001 9183 046 001 1 4 Coil Muel...

Page 106: ...12 A 1 11 5 3 2 4 3 Top Soap Box Design Top Soap Box 4 Valve Design 14 15 Part 8533 097 001 11 16 106...

Page 107: ...3 Clip Push 9083 121 001 9083 121 001 4 4 Vacuum Breaker 9610 001 001 9610 001 001 9610 001 002 1 5 Bracket Vacuum Breaker 9029 077 001 9029 077 001 9029 077 001 1 Screw 9545 008 026 9545 008 026 9545...

Page 108: ...rew Valve to Bracket 12ABx1 2 9545 008 026 2 13 Tube Assy Drain 9915 118 002 1 Screw Tube Bracket to Base 1 4Bx3 4 9545 030 002 2 14 Hose Overflow to drain 9242 449 002 1 Clamp Overflow 8654 117 018 2...

Page 109: ...1 2 9 7 Cylinder 21 19 20 18 17 16 15 14 13 12 11 10 9 8 7 5 6 4 3 2 1 14 5 6 1 33 Part 8533 097 001 11 16 109...

Page 110: ...3 Ring 8640 417 005 8640 417 005 1 10 Bolt 1 2 13 x 2 Rings to Base 9545 017 013 9545 017 013 2 11 Nut Wizloc 1 2 x 13 8640 417 005 8640 417 005 2 12 Washer Flat 1 2 8641 581 026 8641 581 026 2 13 Hos...

Page 111: ...Part 8533 097 001 11 16 111 21 5 6 1 16 4 2 15 7 8 9 3 18 1 14 15 13 17 10 11 12 5 6 4 19 20 1 2 4 3 17...

Page 112: ...Bracket 9029 229 001 9003 229 001 1 Screw 10Bx1 4 rear channel bracket 9545 008 001 9545 008 001 2 Screw Trough Bracket 9545 008 026 9545 008 026 9545 008 026 3 11 Transformer Control Primary Voltage...

Page 113: ...9558 025 001 9558 025 001 1 Screw Mtg 8Bx1 4 9545 045 001 9545 045 001 9545 045 001 2 Terminal Block Assy Injector 9897 032 002 9897 032 002 9897 032 002 1 Cover Electrical 9074 267 001 9074 267 001 9...

Page 114: ...Electrical Components Top Compartment Electronic Pressure Sensor 4 11 13 12 10 9 8 7 6 5 3 2 1 Part 8533 097 001 11 16 114...

Page 115: ...Support Trough Bracket 9029 061 001 9029 061 001 9029 061 001 1 Angle Trough to Rear Channel Bracket 9003 229 001 9003 229 001 1 Screw 10Bx1 4 rear channel bracket 9545 008 001 9545 008 001 2 Screw Tr...

Page 116: ...WN0600XA 12EN2X SSKCS USX Schematic Diagram OPL Maxi Load 40lb Wiring Schematic 12 Part 8533 097 001 11 16 116...

Page 117: ...WN0900XA 12EN2X SSKCS USX Schematic Diagram Part 8533 097 001 11 16 117...

Page 118: ...WN1200XA 12EN2X SSKCS USX Schematic Diagram 1 Part 8533 097 001 11 16 118...

Page 119: ...Part 8533 097 001 11 16 119 Notes...

Page 120: ...Part 8533 097 001 11 16 120 Notes...

Page 121: ...Part 8533 097 001 11 16 121 Section 7 Electric Heated Models...

Page 122: ...rshoot the set temperature by 1 degree to 3 degree This is to assure set temperature will be maintained throughout a normal bath time of 10 20 minutes The heaters will engage if the bath temperature d...

Page 123: ...ibration point and display temperature The display is updated every 5 seconds so make adjustments in very small increments Be sure to allow ample time for display to respond to updates If adjustments...

Page 124: ...002 3 Screw 10Bx1 2 9545 008 026 9545 008 026 9545 008 026 3 Screw 10 32x1 2 9545 012 003 9545 012 003 9545 012 003 3 Screw 6Bx3 8 9545 031 003 9545 031 003 9545 031 003 2 Screw 6ABx3 4 9545 031 010 9...

Page 125: ...268 001 8507 268 001 1 Instructions Spin Direction 8507 274 001 8507 274 001 8507 274 001 1 Schematic Wirng Diagram 9506 571 001 9506 573 001 9506 576 001 1 Owners Booket 8514 241 001 8514 244 001 851...

Page 126: ...Part 8533 097 001 11 16 126 3 4 6 12 4 5 11...

Page 127: ...Assembly BLU YEL 12 8220 064 001 8220 064 001 8220 064 001 1 6 Heater Element 9870 087 001 6 6 Heater Element 9870 087 001 9870 087 001 9 7 Wire Assy Jumper BLK 4 8 8220 085 001 8220 085 001 8220 085...

Page 128: ...WN0600EA 13XN Part 8533 097 001 11 16 128...

Page 129: ...WN0900EA 13XN Part 8533 097 001 11 16 129...

Page 130: ...WN1200EA 13XN Part 8533 097 001 11 16 130...

Page 131: ...Part 8533 097 001 11 16 131 Notes...

Page 132: ...Part 8533 097 001 11 16 132 Notes...

Page 133: ...Part 8533 097 001 11 16 133 Section 8 Steam Heated Valve Kit...

Page 134: ...fle steam 9915 123 001 9915 123 001 9915 123 001 1 PCB assy temp control 9799 013 001 9799 013 001 9799 013 001 1 Sensor assy thermistor 10k 9501 005 002 9501 005 002 9501 005 002 1 Wiring harness tem...

Page 135: ...clamp provided and place it around the body of the steam valve just below the steam valve solenoid housing Reattach the clamp ends and attach the steam valve to the steam valve bracket by sliding the...

Page 136: ...e rota tion The cylinder will resume normal operation once the water bath temperature is within 5 degrees of the programmed temperature Cycle countdown time display will stop while valve is engaged Du...

Page 137: ...with any other cycle changes as previously discussed To exit the program mode and accept all changes press the red Stop button while any one of the nine bath lights top row of lights are lit The Sele...

Page 138: ...l board is removed the programmed temperature values are retained in all baths and the water valves to fill that bath are chosen based on the programmed temperature Steam Heated Washer Schematics Cont...

Page 139: ...WN0600SA 12XN Part 8533 097 001 11 16 139...

Page 140: ...WN0900SA 12XN Part 8533 097 001 11 16 140...

Page 141: ...WN1200SA 12XN Part 8533 097 001 11 16 141...

Page 142: ...Part 8533 097 001 11 16 142 Notes...

Page 143: ...x sskcs vrx 50 1ph 230 240v 100 9999 665 006 Wn0900ea 58cn2x sskcs vrx 50 3ph 400v Heated Electric 100 9999 665 004 Wn0900ea 68xn2x sskcs vrx 50 3ph 400v Heated Electric 100 9999 669 002 Wn1200xa 39xn...

Page 144: ...220 065 018 8220 065 018 8220 065 031 1 4 Transformer Control 8711 008 001 8711 008 001 8711 008 001 1 Instructions Transformer Connections 8507 230 003 8507 230 003 8507 230 003 1 Wire Assembly RED 8...

Page 145: ...79 194 003 2 5 Solenoid 24VAC 50Hz 9536 082 001 9536 082 001 9536 082 001 1 6 Thermoacuator 24 VAC 50Hz 9586 001 003 9586 001 003 9586 001 003 2 Screw 10 32 TT X1 2 9545 008 027 9545 008 027 9545 008...

Page 146: ...01 9534 350 001 1 6 Thermoactuator Door Lock Relay 24v 9586 001 003 9586 001 003 9586 001 003 2 5 Arm Door Lock 9001 063 001 9001 063 001 9001 063 001 1 4 Spacer Plastic 9538 157 021 9538 157 021 9538...

Page 147: ...l Marker injector 24v 9558 028 002 9558 028 002 9558 028 002 1 Terminal Lug Solderless 8652 134 002 8652 134 002 8652 134 002 1 Angle support Trough 9003 229 001 9003 308 001 1 Contol Trough only 9839...

Page 148: ...Part 8533 097 001 11 16 148 WN0600XA 39XN...

Page 149: ...Part 8533 097 001 11 16 149 WN0900XA 39XN...

Page 150: ...Part 8533 097 001 11 16 150 WN1200XA 39XN...

Page 151: ...rip Terminal Marker injector 24v 9558 028 001 9558 028 001 1 Controlsassembly Trough 9857 152 004 9857 179 001 1 2 Heater Assembly 9870 087 001 9 2 Heater Assembly 9870 087 001 6 Terminal Block Power...

Page 152: ...Part 8533 097 001 11 16 152 50HZ Electric Heated Models 1 2 3 4 2...

Page 153: ...064 001 1 Wire assy Grn 11 8220 064 055 8220 064 055 1 Wire assy Red 22 8220 065 011 8220 065 011 1 Wire Assy Yel 8 8220 065 012 8220 065 012 1 Wire assy Vio 8 8220 065 013 8220 065 013 1 Wire Assy Re...

Page 154: ...WN0600EA 68XN Part 8533 097 001 11 16 154 Part 8533 053 001 2 09 rev 2...

Page 155: ...WN0900EA 68XN Part 8533 097 001 11 16 155 Part 8533 053 001 2 09 rev 2...

Page 156: ...WN1200EA 68XN Part 8533 097 001 11 16 156 Part 8533 053 001 2 09 rev 2...

Page 157: ...Part 8533 097 001 11 16 157 Section 10 Maintenance...

Page 158: ...k the drive belt for wear and proper tension Step 2 Clean lint and other foreign material from around drive motor Step 3 Check all water connections for leaks Step 4 Wipe and clean the inside of the w...

Page 159: ...Part 8533 097 001 11 16 159 Notes...