![Dexter Laundry Wn0600ea-13en2x-sskcs-usx Parts & Service Manual Download Page 28](http://html1.mh-extra.com/html/dexter-laundry/wn0600ea-13en2x-sskcs-usx/wn0600ea-13en2x-sskcs-usx_parts-and-service-manual_2490411028.webp)
Part # 8533-097-001 11/16
28
Programming Instructions
Editing an Existing Cycle
There are 29 preset wash cycles programmed into the washer at the factory. Although these cycles are
common industry cycles, there may be a need to tailor the cycle to meet an exact application. This can easily
be done with the following instructions.
Note:
It is recommended when changes are made to one or more
of the preset programs that the cycle number and the changes be documented for later reference. Blank
cycle sheets have been provided at the end of the Preset Cycle Information section.
1.
Turn on the power to the washer.
2.
Turn the Advance/Run/Program key to the Program position (Program Mode LED lights).
The Select Cycle LED is lit.
3.
Select the cycle to be edited by using the SCROLL UP/SCROLL DOWN buttons.
The selection is made when the number displayed corresponds with the desired cycle.
4.
Push the green ENTER button.
Once depressed, the first of the nine cycle segment LED’s will light (top row). The cycle segments
are: Flush, Pre-wash, Wash, Rinse 1, Rinse 2, Rinse 3, Rinse 4, Rinse 5 and Final Rinse/Extract. The
Select Cycle LED is out.
5.
Use the SCROLL UP / SCROLL DOWN buttons to light the cycle segment to be changed.
The sequence of steps below is repeated for each cycle segment until all required segments are edited. The
previously stored parameters will appear as each part of the segment data is reviewed.
6.
Push the green ENTER button.
The Cycle Time LED lights (lower row of LED’s) and the segment LED is out. The tumble time for this
segment will be shown on the display. If no change is required, then continue to the next instruction.
If this value requires changing, then use the
SCROLL UP/SCROLL DOWN
buttons to change the
tumble time, in 1 minute increments, to the desired value, then continue to the next instruction.
Settings range is from 0 minutes to 30 minutes, except for the Final Rinse/Extract segment, where
the setting range is 1 minute to 30 minutes.
REMINDER:
If the tumble time is set to zero, the
segment will be skipped in the wash cycle.
7.
Push the green ENTER button. (The wash time has now been entered.)
The Water Temperature LED lights and the Cycle Time LED is out. The water temperature for this
segment is displayed. If no change is required, then continue to the next instruction. If a change
is required, then use the
SCROLL UP/SCROLL DOWN
buttons to change the water temperature.
HH is all hot water, CC is all cold water, CH is an even mix of hot and cold water, and EE is a no
water bath. Entering a temperature value of 20-90 C will result in a heated bath, if temperature of
fill water is less than programmed temperature. When the desired water temperature is selected,
continue to the next instruction.
8.
Push the green ENTER button. (The water temperature has now been entered.)
The Water Level LED lights and the Water Temperature LED is out. The water level for this segment
is displayed. If no change is required, then continue to the next instruction. If a change is required,
then use the
SCROLL UP/SCROLL DOWN
buttons to change the water level. “HI” is a high water
level and “LO” is a low water level. When the desired water level is selected, continue to the next
instruction.When the No Water bath is selected, the water level has no effect. Either water level
can be selected.
9.
Push the green ENTER button. (The water level has now been entered.)
The Injection Source LED lights and the Water Level LED is out. The injection source for this segment
is displayed. If no change is required, then continue to the next instruction. If a change is required,
Summary of Contents for Wn0600ea-13en2x-sskcs-usx
Page 11: ...11 Section 1 Machine Dimensions...
Page 14: ...T 600 Mounting Pad Dimensions Part 8533 097 001 11 16 14...
Page 15: ...T 900 Mounting Pad Dimensions Part 8533 097 001 11 16 15...
Page 16: ...T 1200 Mounting Pad Dimensions Part 8533 097 001 11 16 16...
Page 17: ...Part 8533 097 001 11 16 17 Notes...
Page 18: ...Part 8533 097 001 11 16 18 Notes...
Page 19: ...19 Section 2 Machine Installation Operating Instructions...
Page 26: ...Part 8533 097 001 11 16 26 Notes...
Page 27: ...Part 8533 097 001 11 16 27 Section 3 Machine Programming Instructions...
Page 39: ...Part 8533 097 001 11 16 39 Section 4 Trouble Shooting...
Page 42: ...Part 8533 097 001 11 16 42 WN____ Input Output PCB Board...
Page 43: ...Part 8533 097 001 11 16 43 WN____ Microprocessor PCB Board...
Page 53: ...53 Section 5 Machine Service Procedures...
Page 71: ...Water Level Part 8533 097 001 11 16 71...
Page 76: ...WN0900XA 12EN2X SSKCS USX Schematic Diagram Part 8533 097 001 11 16 76...
Page 77: ...WN1200XA 12EN2X SSKCS USX Schematic Diagram 1 Part 8533 097 001 11 16 77...
Page 78: ...Part 8533 097 001 11 16 78 Notes...
Page 85: ...1 12 2 3 4 5 6 7 8 9 10 13 14 15 16 5 9 13 14 10 9 Part 8533 097 001 11 16 85 11...
Page 95: ...11 7 9 8 10 10 13 12 13 15 14 16 18 8 9 11 8 9 Part 8533 097 001 11 16 95...
Page 101: ...9 15 16 10 11 12 Part 8533 097 001 11 16 101 17 Plunger Switch 1 3 2 4 5 6 7 8 5...
Page 117: ...WN0900XA 12EN2X SSKCS USX Schematic Diagram Part 8533 097 001 11 16 117...
Page 118: ...WN1200XA 12EN2X SSKCS USX Schematic Diagram 1 Part 8533 097 001 11 16 118...
Page 119: ...Part 8533 097 001 11 16 119 Notes...
Page 120: ...Part 8533 097 001 11 16 120 Notes...
Page 121: ...Part 8533 097 001 11 16 121 Section 7 Electric Heated Models...
Page 126: ...Part 8533 097 001 11 16 126 3 4 6 12 4 5 11...
Page 128: ...WN0600EA 13XN Part 8533 097 001 11 16 128...
Page 129: ...WN0900EA 13XN Part 8533 097 001 11 16 129...
Page 130: ...WN1200EA 13XN Part 8533 097 001 11 16 130...
Page 131: ...Part 8533 097 001 11 16 131 Notes...
Page 132: ...Part 8533 097 001 11 16 132 Notes...
Page 133: ...Part 8533 097 001 11 16 133 Section 8 Steam Heated Valve Kit...
Page 139: ...WN0600SA 12XN Part 8533 097 001 11 16 139...
Page 140: ...WN0900SA 12XN Part 8533 097 001 11 16 140...
Page 141: ...WN1200SA 12XN Part 8533 097 001 11 16 141...
Page 142: ...Part 8533 097 001 11 16 142 Notes...
Page 148: ...Part 8533 097 001 11 16 148 WN0600XA 39XN...
Page 149: ...Part 8533 097 001 11 16 149 WN0900XA 39XN...
Page 150: ...Part 8533 097 001 11 16 150 WN1200XA 39XN...
Page 152: ...Part 8533 097 001 11 16 152 50HZ Electric Heated Models 1 2 3 4 2...
Page 154: ...WN0600EA 68XN Part 8533 097 001 11 16 154 Part 8533 053 001 2 09 rev 2...
Page 155: ...WN0900EA 68XN Part 8533 097 001 11 16 155 Part 8533 053 001 2 09 rev 2...
Page 156: ...WN1200EA 68XN Part 8533 097 001 11 16 156 Part 8533 053 001 2 09 rev 2...
Page 157: ...Part 8533 097 001 11 16 157 Section 10 Maintenance...
Page 159: ...Part 8533 097 001 11 16 159 Notes...