54
Multimat
Easy
6 Controls
‹
View function (soldering)
During a firing program
without vacuum
, you can lower
the firing platform by pressing the
Í
key to inspect the
firing object. Stop the downward movement by pressing
the
È
key.
The
firing time countdown is suspended
, and the cursor
will move to the firing temperature. Use the cursor keys to
increase/decrease the firing temperature
as required.
Then press the
È
key to
move the firing platform back
off
and to close the chamber. Closing the chamber con-
tinues the firing program. After a temperature adjustment,
a maximum
post-firing
time of three minutes can be
provided; the post-firing time is counted up on the display
starting from zero. Post-firing can be terminated at any
time by pressing the
start stop
key.
‹
Entering standby mode
The Multimat
®
Easy Standby mode optimizes the
mois-
ture level
inside the firing chamber and keeps
moisture
away from the
insulation
. Standby mode means constant
heating
at a temperature of e.g. 120 °C;
vacuum
may be
added if required.
Once you have turned on the unit using the
on off
key,
the
standby mode
is entered
automatically
if activated
(see below).
Once you use the
on off
key to turn on the control func-
tion,
standby mode will be turned off
. As soon as you
turn off
the control function again, the unit will return to
standby mode.
To activate the standby function, you will first have to set
the standby temperature in the
Standby temperature
menu (see
“Menu explanations”
):
In the
Standby Vacuum
menu you can select whether
the vacuum pump is to be activated in addition to the
heater:
‹
Fast cooling or manual fast cooling
Fast cooling means that the vacuum pump is turned on
immediately
after termination of the program
once the
firing chamber has opened
and will
suck
in air through
the firing chamber until the
base temperature is reached
.
As fast cooling is activated, the display shows an asterisk
at position
(2)
(see
“Display”
).
If
manual cooling
is required, you need to turn off auto-
matic cooling by setting the corresponding
parameter to 0
(see
“Display”
).
The
fast-cooling
mode
can be turned on or off in the
menus (see “
Menu explanations”
).
To start
manual cooling
, wait for the program to termi-
nate and then press the
Í
key. The firing platform will
be lowered, and the vacuum pump will run until the base
temperature is reached.
Fast cooling
[on/off]
Standby temperature
[°C/°F]
Standby Vacuum
[on/off]
Summary of Contents for Multimat Easy
Page 2: ......
Page 33: ...33 MultimatEasy...
Page 63: ...63 MultimatEasy...
Page 93: ...93 MultimatEasy...
Page 123: ...123 MultimatEasy...
Page 153: ......
Page 154: ...For further information www dentsply degudent com 50572501 a Stand Last revision 04 2008...