Chapter 8 Optional Cards
MS300 (IP66 / NEMA 4X)
8-11
Environment
Noise immunity
ESD (IEC 61800-5-1, IEC 6100-4-2)
EFT (IEC 61800-5-1, IEC 6100-4-4)
Surge Test (IEC 61800-5-1, IEC 6100-4-5)
Conducted Susceptibility Test (IEC 61800-5-1, IEC 6100-4-6)
Operation / Storage
Operation: -10–50 ºC (temperature), 90 % (humidity)
Storage: -25–70 ºC (temperature), 95 % (humidity)
Shock / Vibration resistance International standards:
IEC61131-2, IEC68-2-6 (TEST Fc) / IEC61131-2 & IEC 68-2-27 (TEST Ea)
Installation
PROFIBUS DP connector pin assignment
PIN
PIN name
Definition
1
6
5
9
1
-
Not defined
2
-
Not defined
3
Rxd / Txd-P
Sending / receiving data P(B)
4
-
Not defined
5
DGND
Data reference ground
6
VP
Power voltage – positive
7
-
Not defined
8
Rxd / Txd-N
Sending / receiving data N(A)
9
-
Not defined
LED Indicator & Troubleshooting
There are two LED indicators on
the
CMM-PD01: POWER LED and NET LED. POWER LED displays the
status of the working power. NET LED displays the connection status of the communication.
POWER LED
LED status
Indication
Corrective Action
Green light on Power supply in normal status.
No action is required.
Off
No power
Check if the connection between the CMM-PD01
and the AC motor drive is normal.
NET LED
LED status
Indication
Corrective Action
Green light on Normal status
No action is required.
Red light on The CMM-PD01 is not connected to
PROFIBUS DP bus.
Connect the CMM-PD01 to the PROFIBUS DP bus.
Red light
flashes
Invalid PROFIBUS communication
address
Set the PROFIBUS address of the CMM-PD01
between 1–125 (decimal).
Orange light
flashes
The CMM-PD01 fails to
communicate with AC motor drive.
Switch off the power and check whether the
CMM-PD01 is installed correctly and connected
normally to the AC motor drive.
Summary of Contents for Compact Drive MS300 IP66/NEMA 4X Series
Page 3: ......
Page 10: ...Chapter 1 Introduction MS300 IP66 NEMA 4X 1 3 1 2 Model Name 1 3 Serial Number...
Page 18: ...Chapter 1 Introduction MS300 IP66 NEMA 4X 1 11 This page intentionally left blank...
Page 24: ...Chapter 2 Dimensions MS300 IP66 NEMA 4X 2 6 This page intentionally left blank...
Page 28: ...Chapter 3 Installation MS300 IP66 NEMA 4X 3 4 This page intentionally left blank...
Page 29: ...Chapter 4 Wiring MS300 IP66 NEMA 4X 4 1 Chapter 4 Wiring 4 1 System Wiring Diagram 4 2 Wiring...
Page 32: ...Chapter 4 Wiring MS300 IP66 NEMA 4X 4 4 4 2 Wiring Figure 4 2...
Page 34: ...Chapter 4 Wiring MS300 IP66 NEMA 4X 4 6 This page intentionally left blank...
Page 83: ...Chapter 7 Optional Accessories MS300 IP66 NEMA 4X 7 33 The drive with MKMX SWA...
Page 85: ...Chapter 7 Optional Accessories MS300 IP66 NEMA 4X 7 35 The drive with MKMX SWB...
Page 87: ...Chapter 7 Optional Accessories MS300 IP66 NEMA 4X 7 37 The drive with MKMX SWC...
Page 126: ...Chapter 10 Digital Keypad MS300 IP66 NEMA 4X 10 8 This page intentionally left blank...