interval value
: in seconds.
The range is from 15 to 86400 seconds.
The default is
20 seconds
.
Back-Off Mechanism
If the sampling rate for an interface is set to a very low value, the CPU can get overloaded with flow samples
under high-traffic conditions.
In such a scenario, a binary back-off mechanism gets triggered, which doubles the sampling-rate (halves the
number of samples per second) for all interfaces. The backoff mechanism continues to double the sampling-
rate until the CPU condition is cleared. This is as per sFlow version 5 draft. After the back-off changes the
sample-rate, you must manually change the sampling rate to the desired value.
As a result of back-off, the actual sampling-rate of an interface may differ from its configured sampling rate.
You can view the actual sampling-rate of the interface and the configured sample-rate by using the
show
sflow
command.
sFlow on LAG ports
When a physical port becomes a member of a LAG, it inherits the sFlow configuration from the LAG port.
Enabling Extended sFlow
Extended sFlow packs additional information in the sFlow datagram depend on the type of sampled packet.
The platform supports
extended-switch
information processing only.
Extended sFlow packs additional information in the sFlow datagram depending on the type of sampled
packet. You can enable the following options:
•
extended-switch
— 802.1Q VLAN ID and 802.1p priority information.
•
extended-router
— Next-hop and source and destination mask length.
•
extended-gateway
— Source and destination AS number and the BGP next-hop.
NOTE:
The entire AS path is not included. BGP community-list and local preference information are not
included. These fields are assigned default values and are not interpreted by the collector.
• Enable extended sFlow.
sflow [extended-switch] [extended-router] [extended-gateway] enable
By default packing of any of the extended information in the datagram is disabled.
• Confirm that extended information packing is enabled.
show sflow
sFlow
976
Summary of Contents for S4048T
Page 1: ...Dell Configuration Guide for the S4048T ON System 9 10 0 1 ...
Page 98: ... saveenv 7 Reload the system uBoot mode reset Management 98 ...
Page 113: ...Total CFM Pkts 10303 CCM Pkts 0 LBM Pkts 0 LTM Pkts 3 LBR Pkts 0 LTR Pkts 0 802 1ag 113 ...
Page 411: ...mode transit no disable Force10 Resilient Ring Protocol FRRP 411 ...
Page 590: ...Figure 67 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 590 ...
Page 646: ...Figure 87 Configuring Interfaces for MSDP Multicast Source Discovery Protocol MSDP 646 ...
Page 647: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 647 ...
Page 653: ...Figure 91 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 653 ...
Page 654: ...Figure 92 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 654 ...
Page 955: ...Figure 119 Single and Double Tag First byte TPID Match Service Provider Bridging 955 ...