About Your System
35
Warning: The current memory
configuration is not
validated. Change it to the
recommended memory
configuration or press any
key to continue.
This warning message will be displayed
when there is no any memory
configuration error, but the memory
configuration is not recommended by
Dell.
Alert! Redundant memory
disabled! Memory
configuration does not
support redundant memory.
Redundant memory was set to enabled in
CMOS, but the current configuration
does not support redundant memory.
Attempting to update Remote
Configuration. Please wait…
Remote Configuration request has been
detected and is being processed.
Caution! NVRAM_CLR jumper is
installed on system board
NVRAM_CLR jumper is installed.
CMOS has been cleared. NVRAM_CLR
jumper should be removed.
CPUs with different cache
sizes detected
The system does not support running
with processors with mismatched cache
sizes
Decreasing available Memory
One or more DIMMs improperly seated
or faulty
Diskette drive 0 seek failure
Faulty or improperly inserted diskette,
incorrect configuration settings in System
Setup program, loose diskette/tape drive
interface cable, or loose power cable
Replace the diskette.
Diskette read failure
Faulty diskette, faulty or improperly
connected diskette/tape drive interface
cable, or loose power cable
Diskette subsystem reset
failed
Faulty diskette/tape drive controller
Drive not ready
Diskette missing from or improperly
inserted in diskette drive
Table 1-6. System Messages
System Message
Corrective Action
Summary of Contents for PowerEdge R900
Page 1: ...Dell PowerEdge R900 Systems Hardware Owner s Manual ...
Page 10: ...10 Contents Glossary 171 ...
Page 40: ...40 About Your System ...
Page 56: ...56 Using the System Setup Program ...
Page 126: ...126 Installing System Components ...
Page 164: ...164 Jumpers and Connectors ...
Page 190: ...190 Index ...