To save any changes you make in this page, click
Apply Changes
. If you don't want to save the changes, click
Refresh
.
CLI Commands
The following table summarizes the equivalent CLI command for items in the
Switch/Jumbo Frame
page.
Example
Console(config)#jumbo frame
Console(config)#
Firmware Upgrade
From the
Firmware
page, you can configure the system to download a new version of the management software. The switch can contain two software code
files, one of which is set as the
Start-Up
file. This allows you to try a new version of the software without overwriting the previous version.
The
Firmware
page contains the following fields:
l
Current Operation Code Version
It also contains the following editable fields:
l
TFTP Server IP Address
—
Specifies the server from which the system must retrieve the new version of the software.
l
Source File Name
—
Specifies the path and name of the software file to download.
l
Destination File Name
—
Specifies the file to be replaced.
l
Remove Operation Code Image File
—
Deletes a software file from the switch.
l
Start-Up Operation Code File Name
—
Indicates which Operation Code file you want to run. Select the filename from the drop-down menu.
Uploading Operation Code to a Server
1.
In the
Transfer Operation Code Image File to Server
field, enter the IP address of the Trivial File Transfer Protocol (TFTP) server in the
TFTP Server
IP Address
field.
2.
In the
Source File Name
field, select the file to upload from the drop- down menu.
3.
In the
Destination File Name
field, type a name for the file.
4.
Click
Transfer to Server
.
Downloading Operation Code from a Server
1.
In the
Transfer Operation Code Image File from Server
field, enter the IP address of the TFTP server in the
TFTP Server IP Address
field.
2.
In the
Source File Name
field, type the filename of the software code file to download.
3.
For the
Destination File Name
, select a filename from the drop-down menu to replace an existing file, or specify a new filename (with no more than 32
characters). Filenames are case sensitive and cannot contain spaces. The switch can contain only two software code files. You cannot download a third
file; you must first replace an existing file or remove a file.
4.
Click
Transfer from Server
.
Deleting an Operation Code File from the Switch
1.
In the
Remove Operation Code Image File
field, select the file to delete from the drop-down menu.
2.
Click
Remove File
.
Command
Usage
jumbo
frame
Use this command to enable jumbo frames to be forwarded through the switch. Use the
no
form to disable jumbo frames.
NOTE:
The switch is shipped with one software code file installed (the filename is similar to
PC5224_v1.00.00.00
), which is set as the start- up file.