64
Managing and Recovering a Remote System
www
.dell.com | support.dell.com
Viewing Information About Existing Alerts
Click an alert in the
SNMP Alert List to
display the properties for existing SNMP alerts.
See Table 4-9 for descriptions.
NOTE:
During the first 40 seconds after a DRAC 4 reset, the DRAC 4 is synchronizing with the system
BMC and the managed system service. If an alert is generated during this time, some of the values may
be reported as "unknown." The time field contains the number of seconds since DRAC 4 startup.
After synchronization has completed, all values are reported correctly.
Table 4-8. Severity Options
Option
Description
Informational
Select the check boxes in this column to cause the DRAC 4 to send an alert if
the corresponding event listed under
Alert Description
occurs with a severity
of
Informational
(lowest severity).
Warning
Select the check boxes in this column to cause the DRAC 4 to send an alert if
the corresponding event listed under
Alert Description
occurs with a severity
of
Warning
(medium severity).
Severe
Select the check boxes in this column to cause the DRAC 4 to send an alert if
the corresponding event listed under
Alert Description
occurs with a severity
of
Severe
(highest severity).
Alert Description
Lists the following events monitored by the DRAC 4. An alert (specified as
either informational, warning, or severe) is sent when the event is triggered at
the level of severity you selected in the check boxes to the left.
NOTE:
For information about how to manage events, see the
Server Administrator User's Guide
.
•
Select All
— Monitors all of the sensors available on the system.
•
System Temperature Sensors
— Monitors the temperature sensors on the system.
•
System Voltage Sensors
— Monitors the voltage sensors on the system.
•
System Fan Sensors
— Monitors the system fan speed (RPM).
•
System Miscellaneous Sensors
— Monitors other available system sensors
such as chassis intrusion.
Summary of Contents for DRAC 4
Page 28: ...28 DRAC 4 Overview w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 84: ...84 Managing and Recovering a Remote System w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 148: ...148 Troubleshooting w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 182: ...182 racadm Subcommand Man Pages w w w d e l l c o m s u p p o r t d e l l c o m ...