Configure serial over LAN (SOL)
About this task
The PowerProtect system provides the ability to access the serial console through the iDRAC interface.
Configuring SOL is optional.
If SOL is already enabled on the system, no further action is required.
CAUTION:
Do not use iDRAC to change the storage configuration, system settings, or BIOS settings, as making
changes will impact system functionality. Contact Support if changes are required in any of these areas.
CAUTION:
Enabling SOL disables the serial console.
Steps
1. In a web browser, type the iDRAC IP address specified during iDRAC configuration.
2. Login with the user name root. The default password is the system serial number on the PSNT.
3. Select
Configuration
>
BIOS Settings
>
Serial Communications
.
4. Verify the following values are configured, and specify any that are not set as listed:
●
Serial Communication
: Auto
●
Serial Port Address
: Serial Device1=COM2, Serial Device2=COM1
●
External Serial Connector
: Serial Device 2
●
Failsafe Baud Rate
: 115200
●
Remote Terminal Type
: VT100/VT220
●
Redirection After Boot
: Enabled
5. Click
Apply
to save any changes.
6. Select
iDRAC Settings
>
Connectivity
>
Serial Over LAN
.
7. Specify the following values if they are not already configured:
●
Enable Serial Over Lan
: Enable
●
Baud Rate
: 115.2 kbps
●
Channel Privilege Level Limit
: Administrator
●
Redirect Enable
: Enable
●
Escape Key
: ^\ (
Ctrl + \
)
8. Click
Apply
to save any changes.
9. Select
iDRAC Settings
>
Services
.
10. Specify the following values if they are not already configured:
a. Select
Enabled for SSH
.
b. Verify the Port Number is set to 22.
11. Click
Apply
to save any changes.
12. Select
Configuration
>
BIOS Settings
>
Serial Communications
.
13. Click
Apply and Reboot
.
14. Select
Maintenance
>
Job Queue
and verify the
Configure: BIOS.Setup
job is complete.
NOTE:
Click
Refresh
to get the latest status
Change the iDRAC network port
About this task
iDRAC provides the ability to disable the dedicated iDRAC Ethernet port and assign the iDRAC connection to share one of the
network daughter card Ethernet ports. This step is optional.
66
Configure System for Use
Summary of Contents for PowerProtect DD9400
Page 1: ...Dell EMC PowerProtect DD9400 System Installation Guide September 2020 Rev 03...
Page 57: ...Figure 65 Single node DD9400 with DS60 shelves Connect Cables and Power On 57...
Page 58: ...Figure 66 HA DD9400 with DS60 shelves 58 Connect Cables and Power On...
Page 63: ...Figure 72 Routing cables through the CMA brackets Connect Cables and Power On 63...