CL5503
Figure 52. 30"-34" Marking
5. Slide the inner rail mechanism to the rear of the rail until the 30-34" mark is visible. If the inner mechanism is locked,
depress the leaf spring to free it.
6. Adjust the hardware to make sure the mounting holes are aligned with the mounting slots.
7. Secure the length adjustment bracket in place using both screws and nuts that were removed earlier.
8. Repeat for the other rail.
Next steps
After the rails are adjusted to the proper length, install the rails in the rack.
Installing the rails in a third-party rack
The rails are shipped with 6.8 mm adapters that are designed to fit into the NEMA channels of the Dell EMC rack. For third-
party racks, the 6.8 mm adapters must be removed and replaced with rail pins that fit the hole-types in the third-party rack.
About this task
CAUTION:
Exercise care when installing the short rails. Exposed metal edges may be sharp and could damage
cabling or cause injury to personnel.
Refer to the following tables and figures to install each shelf.
The following table shows the rail pins and their suggested use.
Table 6. Pins for third-party racks
Rail Pins from kit
Part Number and Description
Suggested Use
036-028-018
Custom screw, M4 x 10MM
(Quantity: 4 per kit)
Used for any third-party rack. Can be
used in racks with threaded holes.
036-028-016
3.8MM Alignment Pin
(Quantity: 8 per kit)
Used in racks that have M5, #10, or #12
threaded holes.
036-028-017
4.8MM Alignment Pin
(Quantity: 8 per kit)
Used in racks that have M6 threaded
holes.
NOTE:
Each of the rail alignment pins must be located in the middle holes of the bottom two U spaces of the 4U space.
The following table lists the parts that are referenced in
on page 46.
Install the Disk Shelves in the Rack
45
Summary of Contents for PowerProtect DD9400
Page 1: ...Dell EMC PowerProtect DD9400 System Installation Guide September 2020 Rev 03...
Page 57: ...Figure 65 Single node DD9400 with DS60 shelves Connect Cables and Power On 57...
Page 58: ...Figure 66 HA DD9400 with DS60 shelves 58 Connect Cables and Power On...
Page 63: ...Figure 72 Routing cables through the CMA brackets Connect Cables and Power On 63...