Figure 68. Slot numbering
Port numbers
The following port numbering guidelines apply to all I/O modules except the network daughter card:
●
The physical interface name format for the remaining I/O module slots is
eth
Xy
, where X is the slot number and
y
is an
alphanumeric character. For example, eth0a.
●
For most horizontal I/O module NIC interfaces, the port numbering goes from left to right, with eth
X
a on the left.
○
The horizontal I/O module slots on the left-in slots 1-3 are inverted. The port numbering on these I/O modules in these
slots goes from right to left, with eth
X
a on the right.
Slot assignments
The following table lists the slot assignments for the supported I/O modules.
Table 14. I/O module slot assignments
Description
Slot
QLogic, 41164 4 Port, 10GbE SFP+ PCIe, Full Height
5, 8, 1
QLogic, 41164 4 Port, 10GBASE-T PCIe, Full Height
5, 8, 1
QLogic, 41164 4 Port, 10GBASE-T PCIe, Low Profile
6
QLogic, 41262 2 Port, 25Gb SFP28 PCIe, Full Height
5, 8, 1
QLogic, 41262 2 Port, 25Gb SFP28 PCIe, Low Profile
6
HBA330 SAS Controller, 12Gbps Mini card
mini/mono
QAT,INTEL,8970,FH, Avnet p/n 1QA89701G1P5
4
PM8072,SAS12,4P,FH, MicroSemi 2295200-R
3, 7, 5
FC16,QLE2694-DEL-BK,TRG,QP,Full Height
5, 8, 1
16GB NVRAM,Full Height
2
Steps
1. For 10 GBASE-T connections, use one of the following:
●
Unshielded Cat 6 cables with RJ-45 connectors that do not exceed 55m
●
Cat 6A cables with RJ-45 connectors that do not exceed 100m
2. For 10 GbE-SFP+ optical connections, refer to the list of qualified adapters and use an OM1 160 MHz (2 to 26m), OM1 200
MHz (2 to 33m), OM2 400 MHz, (2 to 66m), OM2 500 MHz (2 to 82m), OM3 1500 MHz (2 to 300m), or OM 4 3500 MHz
(2 to 400m) SFP+ optical cable.
3. For 25 GbE-SFP28 connections, use optical cables that support the 25GBASE-SR standard to connect to the 25 GbE-
SFP28 optical transceivers.
4. For 100 GbE connections, use copper direct attach (DAC) cables up to 5 m, or active optical cables up to 30 m.
5. For FC connections, use a qualified OM1, OM2, or OM3 Fibre Channel optical cable:
For 100GbE QSFP28 direct attach copper (DAC) connections, use DAC cables up to 5m
Table 15. Maximum FC cable lengths
Data rate
OM1 maximum length
OM2 maximum length
OM3 maximum length
4 Gbps
70m
150m
380m
8 Gbps
21m
50m
150m
60
Connect Cables and Power On
Summary of Contents for PowerProtect DD9400
Page 1: ...Dell EMC PowerProtect DD9400 System Installation Guide September 2020 Rev 03...
Page 57: ...Figure 65 Single node DD9400 with DS60 shelves Connect Cables and Power On 57...
Page 58: ...Figure 66 HA DD9400 with DS60 shelves 58 Connect Cables and Power On...
Page 63: ...Figure 72 Routing cables through the CMA brackets Connect Cables and Power On 63...