Operation
27
Under normal operation, this will not happen. This is normally left
at the default value.
4. Flow Control ON Buffer Level
Once the High_Water mark has been reached, the “no-input
accepted” mode will continue until the EtherPath has transmitted
enough data to reduce the buffer contents to this point. This is
normally left at the default value.
5. Line_Terminator_Character
This setting is used to change the Line Terminator Character. The
Line Terminator Character causes any data in the buffer to be
transmitted immediately the character is received, provided: This is
the binary value of the trigger charaacter.
•
The EtherPath is being used in “Client” mode.
•
The following setting (Transmit_on_LT_Char) is ON.
6. Transmit_on_LT_Char
When this setting is ON, any data in the buffer will be sent
immediately upon receipt of a Line_Terminator_Character (see
previous setting). When the setting is OFF, the
Line_Terminator_Character has no effect.
In “Server” mode, this setting has no effect.
7. Server End-of-Line Filter
This setting can turn the filter function ON or OFF.
If ON, then when a CR/LF (Carriage Return, Line Feed) character
pair is received, it is converted to a CR only before it is sent to the
serial port output. CR/LF pairs are normally used in the MS-DOS
environment to mark the end of a line, but may cause problems in
other environments.
CR/NULL character pairs are also converted to a CR only.