PORT CONFIGURATION:
Flow Control: NONE
Baud Rate: 9600
Data: 8 Bits Parity: NONE Stop: 1 Bit
Pin 6 Control: FORCED ON
Client Dial Mode: HARDWARE (Pin 6)
RS485: 4-wire (Jumpers set for RS232)
SET PORT CONFIGURATION:
1 Flow Control [0=None, 1=XON/XOFF, 2=RTS/CTS, 3=RTS
Toggle]
2 Baud Rate [0=230400, 1=115200, 2=57600, 3=38400,
4=19200,
5=9600, 6=4800, 7=2400, 8=1200, 9=600,
10=300]
3 Parity bit [0=None, 1=Odd, 2=Even]
4 Data bits [0=7bits, 1=8bits]
5 Stop bits [0=1bit, 1=2bits]
6 Pin 6 Control [0=From Interface, 1=Forced ON]
7 Dial Mode [0=ATD, 1=Hardware (Pin 6)]
8 RS485 Mode [0=4-wire, 1=2-wire]
0 -- Return to previous menu.
EXAMPLE: To set the baud rate to 19200
=> 2 4
Enter Command =>
This screen allows you to change the settings for the RS232 link.
The settings used should match the device connected to the serial
port of the EtherPath.
Note that the EtherPath's serial settings must match the device that