34
TC3 Series Traction Control
www.moretraction.com
Traction Control
This is the primary menu used to tune the traction
control. These parameters can be adjusted using the
Remote Display or optionally using the Profiler
interface software on a PC (Settings>Traction
Control,
See Appendix C
).
Mode is used to set the overall sensitivity of the
system. The larger the setting the more sensitive,
thereby making corrections on smaller slips. Range
is 1-9, default=5.
Mode
Save
+
-
5
Adjust to Desired Sensitivity of
Traction Control. Higher Values
= More Sensitive
(1-9, Default = 5)
Hold is used to force the TC system to hold the
correction for X many revolutions of the measured
shaft to give the vehicle some time to recover before
the correction is removed.
Hold
Save
+
-
3
Minimum Duration in
Measured Shaft Revolutions
that Correction is Held Once a
Correction is Triggered
(0-9, Default = 3)