Handbuch Datafox EVO 3.5 Pure
Seite 116
Datum: 06.08.2018 Version: 04.03.07.XX
Example for Data on Card
:
ID with serial number:
1848989745
List entry for
1848989745
in the file before transferring to the device
Field ID Field Data (binary field) here as hex bytes
1848989745
3031323334353637383941424344454630313
2333435363738394142434445463031323334353637383941 ……
Data after conversion or within the device
Field ID Field Data (binary field) is binary here
1848989745
0123456789ABCDEF0123456789ABCDEF0123456789A …..
The following data will be writen on the ID card:
0123456789ABCDEF0123456789ABCDEF0123456789A …..
Binary the data looks like this:
0x30, 0x31, 0x32, 0x33, 0x34
……
Please note:
When a 3-tone sequence is signaled, the Data-On-Card option is not available on this de-
vice. The option has to be purchased afterwards.