5.9.9.6. change the access control master ID and nob Active Time
To change the access control master ID, the "Configuration dialog for U&Z locking cylinders" dialog
must be used. It contains "Advanced settings" and with a click on it this dialog opens.
Master ID can be set in the range from 1 to 9999. If a device has more than one access control bus,
the access control master ID is the ID of the first bus. The second bus access-control-Master ID + 1
etc.
The Knob Active Time is for presetting how long a radio lock cylinder maintains radio communica-
tion with the FSM when activated. When a transponder booking is made, the access control master
automatically closes the connection after signaling and opening. If the Knob Active Time is less than
required for the transponder booking, the radio lock cylinder switches off and an opening fails. This
happens at e. g. Knob Active Time = 1 (1s). If someone turns the knob of the radio lock cylinder, the
radio connection to the FSM is established and the connection remains active as long as the Knob
Active Time is active. Useful values are between 2 and 10 seconds. By default, this time is set to 3
seconds.