5.9.9.4. Set up the wireless network for cylinder
For setup, DatafoxStudioIV can be used in conjunction with the service key card. To do this, select
"Configuration->Access control->Configure U&Z locking cylinder" in DatafoxStudioIV. With "Update
data" the current configuration is read from the FSM.
Steps of teaching-in the cylinders:
1. hold service key to cylinder
(Service = 20 seconds active (activate cylinder by turning it briefly!))
2. Refresh data in DatafoxStudioIV!
Free addresses are displayed with FFFFFFFFFF, the serial number of the radio lock cylinder and
the status of the modules are displayed for the assigned addresses, as in the dialogue Status of the
access modules.
The "Configuration dialog for U&Z locking cylinders" dialog allows different things to be done.
Advanced settings:
Setting the ZK-Master ID for the device
KnobActiveTime: Time that the cylinder tries to reach the FSM after activation until it goes back to
standby.
Update information on individual locking cylinders (column "Info")
Changing the battery puts the radio lock cylinder into a mode that allows the cover to be removed and
the battery to be changed. To do this, brief communication with the FSM is required. This is achieved
by turning the knob or holding a transponder in front of it.
Teach out: The cylinder is removed from the FSM and can be taught in to another FSM.
Teach-in: To connect a radio lock cylinder to the FSM (the radio lock cylinder then only communicates
with this FSM)