74
4.0 Programming the Unit
4.2 Bar Code Settings
4.2.1
Set Default Parameter
The SE-955 can be reset to two types of defaults: factory defaults or cus-
tom defaults. Scan the appropriate bar code below to reset the SE-955 to
its default settings and/or set the scanner’s current settings as the cus-
tom default.
•
Restore Defaults
- Scan this bar code to reset all default parameters
as follows.
– If custom defaults were set by scanning
Write to Custom De-
faults
, scan
Restore Defaults
to retrieve and restore the scan-
ner’s custom default settings.
– If no custom defaults were set, scan
Restore Defaults
to restore
the factory default values.
Restore Defaults
Set Factory Defaults
Write to Custom Defaults
Low (0x02)
*Medium (0x01)
High (0x00)
4.2.2
Beeper Volume
Parameter # 0x8C
To select a decode beep volume, scan the appropriate bar code.
•
Set Factory Defaults
- Scan this bar code to restore the factory de-
fault values. If custom defaults were set, they are eliminated.
•
Write to Custom Defaults
- Scan this bar code to store the current
scanner settings as custom defaults. Once custom default settings are
stored, they can be recovered at any time by scanning
Restore De-
faults
.
Low Frequency (0x02)
*Medium Frequency (0x01)
High Frequency (0x00)
4.2.3
Beeper Tone
Parameter # 0x91
To select a decode beep frequency (tone), scan the appropriate bar code.
Beeper Frequency Adjustment
(Default: 2500 Hz)
4.2.4
Beeper Frequency Adjustment
Parameter # 0xF0 0x91
This parameter adjusts the frequency of the high beeper tone from the
nominal 2500 Hz to another frequency matching the resonances of the
installation. It is programmable in 10 Hz increments from 1220 Hz to
3770 Hz.
To increase the frequency, scan the bar code below, then scan three
numeric bar codes in
Section 5.5
on page
95
that correspond to the
desired frequency adjustment divided by 10. For example, to set the fre-
quency to 3000 Hz (an increase of 500 Hz), scan numeric bar codes 0, 5,
0, corresponding to 50, or (500/10).
To decrease the frequency, scan the bar code below, then scan three
numeric bar codes in
Section 5.5
on page
95
that correspond to the
value (256 - desired adjustment/10). For example, to set the frequency
to 2000 Hz (a decrease of 500 Hz), scan numeric bar codes 2, 0, 6, cor-
responding to 206, or (256 - 500/10).
To change the selection or cancel an incorrect entry, scan the Cancel bar
code in
Section 5.5.1
on page
95
.