14
Setpoints
Introduction
This section gives you a description of the various setpoints for HRV 5. Information on
how to change the setpoints is described in
the sections ”How to set temperature set-
” page 24 and ”How to set fan speed” page. 25.
Factory setting
The factory settings are as follows:
Setpoint
Factory setting
Setting area
Temperature for
electric heating element,
T
min
18 °C
12
– 25 °C
Temperature for summer
operation, T
max
24 °C
17
– 30 °C
Fan speed, step 1
25 %
750 RPM
25-98 %
but it can never be higher
than step 2
Fan speed, step 2
50 %
1500 RPM
26-99 %
but it can never be lower
than step 1 nor higher than
step 3
Fan speed, step 3
70 %
2250 RPM
27-100 %
but it can never be lower
than step 2
Relation between extract
and supply
100 %
70
– 130 %
But min/max = 750/3000
RPM per fan
T
min
When the supply air temperature falls under the factory setting, the electric heating el-
ement (accessory) will switch on.
T
max
When the extract air temperature rises above the factory setting, summer mode will be
switched on and the heat exchanger switches off.
Fan speeds
Standard setting for the relation between extract air and supply air is 100 %, which
means that the supply air fan is running at the same speed as the extract air fan. Set-
ting scale is from 70 % to 130 %, which means that the supply fan can be set to run
30 % slower or quicker than the extract fan. The function is used partly to compensate
for differences in the counter pressure in the supply air system compared to the extract
air system, partly to ensure a constant negative pressure in the house.
Summary of Contents for HRV 5
Page 1: ...Focus Trust Initiative HRV 5 Service manual DA GB DE No 039994 rev 2 0 08 03 2011...
Page 2: ...2005 layout...
Page 3: ...HRV 5 Service manual EN DA DE No 039994 rev 2 0 08 03 2011...
Page 54: ...52...
Page 104: ...52...
Page 138: ...36 Fortsetzung auf der n chsten Seite...
Page 148: ...46 Abmessungen Abbildung Die Abbildung zeigt die Abmessungen eines HRV 5...
Page 154: ...52 Firmenstempel Datum und Unterschrift...
Page 157: ...2005 layout...