5.3.1 Type Code
Table 5.1
Description
Pos
Possible choice
Product group
1-3
Adjustable Frequency Converters
Series and product type
4-6
Micro Drive
Power size
7-10
0.18-22 kW
Mains voltage
11-12
S2: Single phase 200-240 V AC
T 2: Three phase 200-240 V AC
T 4: Three phase 380-480 V AC
Enclosure
13-15
IP20/Chassis
RFI filter
16-17
HX: No RFI filter
H1: RFI filter class A1/B
H3:RFI filter A1/B (reduced cable length*)
Brake
18
B: Brake chopper included (from 1.5 kW and up)
X: No brake chopper included
Display
19
X: No Local Control Panel
N: Numerical Local Control Panel (LCP)
P: Numerical Local Control Panel (LCP) with potentiometer
Coating PCB
20
C: Coated PCB
X. No coated PCB
Mains option
21
X: No mains option
Adaptation A
22
X: No adaptation
Adaptation B
23
X: No adaptation
Software release
24-27
SXXX: Latest release - std. software
Table 5.2 Type Code Description
How to Order
VLT
®
Micro Drive FC 51 Design Guide
44
MG02K202 - VLT
®
is a registered Danfoss trademark