NOTE
•
Reduce common mode interferences by
establishing a low impedance current path to the
VLT
®
Micro Drive.
•
To ensure optimum EMC performance, use a De-
Coupling plate kit (ordering numbers 132B0106
or 132B0107)
For voltage rating, wire size and fuse selection, see the
VLT
®
Micro Drive Quick Guide, MG02B
.
4.1.17 Dimensions
100
+10
0
300
+20
0
M6
1
W
PE
d
LO
A
D
LINE
5.5
h1
l1
h2
7.8
W1
W2
l2
h
l2
h3
Ø11
Ø5.5
M4(3x)
130BC163.10
Illustration 4.34
Frame
M1
M2
M3
Unit
w
70
75
90
mm
d
55
65
69
mm
h
190
210
300
mm
h3
230
250
340
mm
w1
40
40
55.6
mm
h1
213
233
323
mm
w2
55
59
69
mm
h2
140
166.5
226
mm
l1
45
38.5
68
mm
l2
7.6
8
9.3
mm
PE
M6
M6
M6
metric
Weight
2
3
5
kg
Table 4.8
VLT
®
Micro Drive Selection
VLT
®
Micro Drive FC 51 Design Guide
40
MG02K202 - VLT
®
is a registered Danfoss trademark
4