Specification
Value
EMC immunity for functional safety
EN 61800-5-2 Annex E
Degree of pollution according to EN
60664-1
2
Overvoltage category according to EN/IEC
61800-5-1
III
Output current [%]
100
90
80
70
60
30
35
40
45
50
55
e30bh106.10
Illustration 96: Derating
11.9 Storage
Store the servo system components in a dry, dust-free location with low vibration (v
eff
≦
0.2 mm/s).
The storage location must be free from corrosive gases.
Avoid sudden temperature changes.
Long-term storage
To recondition the electrolytic capacitors, servo drives and system components that are not in service must be connected to a sup-
ply source once per year to allow the capacitors to charge and discharge. Otherwise the capacitors could suffer permanent damage.
AQ377148425069en-000101
/ 130R1213
150 | Danfoss A/S © 2023.08
Specifications
VLT® Servo Drive System ISD 511
Operating Guide