Table 35: AUX user limit current warning (0x2394 / 0x128)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x2394 0x128
AUX user limit cur-
rent warning
Warning
Current on the AUX line has reached
the user-defined limit for warning.
AUX curr
warn
9.4.10 AUX supply failure (0x2395 / 0x129)
This error is valid for DAM 510.
Table 36: AUX supply failure (0x2395 / 0x129)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x2395 0x129
AUX supply fail-
ure
Error
AUX supply failure indicated by
hardware circuit..
AUX supply fail
9.4.11 Current overload trip (0x2396 / 0x15C)
This error is valid for DAM 510.
Table 37: Current overload trip (0x2396 / 0x15C)
Code
PROFINET
®
code Name
Severity (warning/error/trip
lock)
Description
LCP name
0x2396 0x15C
Current overload
trip
Error
Current overload trip error. curr ovld trip
9.4.12 Power overload trip (0x2397 / 0x12B)
This error is valid for PSM 510.
Table 38: Power overload trip (0x2397 / 0x12B)
Code
PROFINET
®
code Name
Severity (warning/error/trip
lock)
Description
LCP name
0x2397 0x12B
Power overload trip Error
Power overload trip error. pwr ovld trip
9.4.13 Mains phase loss (0x3130 / 0x12F)
This error is valid for PSM 510.
Table 39: Mains phase loss (0x3130 / 0x12F)
Code
PROFINET
™
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x3130 0x12F
Mains
phase loss
Error
Mains phase loss detected.
This occurs when a phase on mains is missing, or
when the mains is imbalanced.
phase loss
9.4.14 DC link overvoltage (0x3210 / 0x103)
This error is valid for PSM 510, DAM 510, ACM 510, and ISD 511.