Specifications
Unit
Typical value
Condition
Cooling
–
Via flange and natural convection
–
Mounting
–
Via flange
–
Weight
kg [lb]
4.2 [9.26]
–
11.2.2 Characteristic Data for Power Supply Module (PSM 510)
Table 111: Characteristic Data for PSM 510
Definition
Unit
Power size 1
Power size 2
Power size 3
Input
Mains input voltage
V AC
5.2 Electrical Environmental Conditions
)
Input current @ U
MIN
A
20
34
50
Input power
VA
12.5
22
32
U
AUX
input voltage
V DC
24/48 ±10%
U
AUX
current consumption at 24 V DC
A DC
2.0
U
AUX
current consumption at 48 V DC
A DC
1.0
Output
DC-link voltage
V DC
565–680 ±10%
DC-link capacitance
µF
1800
Rated current I
N
A
20
40
60
Rated power P
N
kW
10
20
30
Peak power P
max
t <3.0 s)
kW
20
40
60
Internal brake resistor
(1)
Peak power P
max
kW
8
Rated power P
N
W
150
Nominal resistance
Ω
15
External brake resistor
Peak power P
max
kW
60
Rated power P
N
kW
7.5
Minimum resistance
Ω
10
General
Protective measures
–
Overload, short-circuit, and ground fault protection
Line filter in accordance with EN 61800-3
–
Category C3
Cooling
–
Integrated fan
AQ377148425069en-000101
/ 130R1213 | 129
Danfoss A/S © 2023.08
Specifications
VLT® Servo Drive System ISD 511
Operating Guide