Pa
r.
No
.
#
Pa
rame
ter de
scri
pt
io
n
De
fa
ult va
lue
(SR = S
ize
rel
ate
d)
4-se
t-up
Change during
op
er-
ati
on
Conve
r-
sion
inde
x
Type
1-
0* Gen
er
al Set
ti
n
g
s
1-0
0
Con
fig
uration Mode
null
Al
l s
et
-up
s
TR
U
E
-
Ui
nt
8
1-0
3
Tor
que Chara
cteristics
[3] Aut
o Energ
y Op
tim.
V
T
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
1-
2* Mot
o
r
Dat
a
1-2
0
Moto
r Po
we
r [kW]
Ex
pressio
nLimit
Al
l s
et
-u
ps
FALSE
1
Ui
nt3
2
1-
21
Moto
r Po
we
r [HP]
Ex
pressio
nLimit
All
se
t-u
ps
FALSE
-2
Uint32
1-2
2
Motor V
oltage
Ex
pressio
nLimit
Al
l s
et
-u
ps
FALSE
0
Ui
nt1
6
1-
23
Moto
r Fre
quen
cy
Expressio
nLi
mit
All
set-
up
s
FALSE
0
U
int16
1-2
4
Moto
r Curren
t
Ex
pressio
nLimit
Al
l s
et
-u
ps
FALSE
-2
Ui
nt3
2
1-2
5
Mo
tor
No
minal Sp
ee
d
Exp
re
ssionLi
mit
All
set-
up
s
FALSE
67
U
int16
1-2
8
Moto
r Ro
tat
ion
Check
[0
] OFF
Al
l s
et
-u
ps
FALSE
-
Ui
nt8
1-2
9
Auto
matic Moto
r Ada
ptat
ion
(AMA)
[0] Off
Al
l s
et
-u
ps
FALSE
-
Ui
nt8
1-
3* Addl
. M
o
tor
D
ata
1-3
0
St
ato
r R
esistance
(R
s)
Ex
pressio
nLimit
Al
l s
et
-u
ps
FA
LS
E
-4
Ui
nt
32
1-3
1
Ro
tor Resi
stan
ce
(
R
r)
Ex
pressio
nLimit
Al
l s
et
-u
ps
FALSE
-4
Ui
nt3
2
1-
35
Mai
n Re
acta
nce (
Xh
)
Ex
pressi
on
Limi
t
Al
l se
t-u
ps
FALSE
-4
Ui
nt3
2
1-3
6
Iron Loss
R
esist
ance (Rfe
)
Ex
pressio
nLimit
Al
l s
et
-u
ps
FALSE
-3
Ui
nt3
2
1-3
9
Mo
tor P
ole
s
Ex
pressio
nLimit
All se
t-u
ps
FALSE
0
U
in
t8
1-
5* Load-I
nd
ep.
S
ett
in
g
1-5
0
Moto
r
Mag
neti
zati
on at Zer
o
Sp
eed
100
%
Al
l s
et
-u
ps
TRU
E
0
Ui
nt
16
1-5
1
M
in
Spe
ed N
ormal
Ma
gne
tiz
in
g [
R
PM
]
Ex
pressio
nLimit
Al
l s
et
-u
ps
TRU
E
67
Ui
nt1
6
1-
52
M
in
Spe
ed N
ormal
M
ag
neti
zin
g [
H
z]
Ex
pressi
on
Limi
t
Al
l se
t-u
ps
TRU
E
-1
U
in
t1
6
1-
6* Load-D
ep
en
d. Set
tg
.
1-6
0
Lo
w
Sp
ee
d Loa
d Compen
sation
100
%
Al
l se
t-u
ps
TRUE
0
Int16
1-6
1
H
igh
Sp
ee
d Loa
d Compen
sati
on
100
%
Al
l s
et
-u
ps
TRU
E
0
Int1
6
1-
62
Slip Compe
nsation
0 %
All
se
t-u
ps
TRUE
0
Int16
1-6
3
Slip
Compe
nsation Tim
e Consta
nt
Ex
pressio
nLimit
Al
l s
et
-u
ps
TRU
E
-2
Ui
nt1
6
1-6
4
R
eso
nance
Damp
ening
100
%
All
set-
up
s
TR
U
E
0
U
int16
1-6
5
Re
sona
nce D
ampen
ing Time
Co
nstan
t
5 ms
Al
l s
et
-u
ps
TRU
E
-3
Ui
nt8
1-
7* Star
t
Adju
st
men
ts
1-7
1
St
art Delay
0.
0 s
Al
l s
et
-u
ps
TRU
E
-1
Ui
nt1
6
1-7
3
Flyi
ng S
tart
[0
] Di
sabl
ed
Al
l se
t-
up
s
FA
LS
E
-
U
in
t8
1-
8* St
op Adj
u
st
me
nt
s
1-8
0
Funct
ion
a
t
Sto
p
[0] Coast
Al
l s
et
-up
s
TR
U
E
-
Ui
nt
8
1-8
1
Mi
n
Speed for
Function at Stop
[R
PM]
Ex
pressio
nLimit
Al
l s
et
-u
ps
TRU
E
67
Ui
nt1
6
1-
82
Mi
n Speed
for
Function
at St
op [Hz]
Ex
pressio
nLimit
All se
t-u
ps
TRUE
-1
U
int16
1-8
6
Trip S
pee
d
Low [R
PM]
0 R
PM
Al
l s
et
-u
ps
TRU
E
67
Ui
nt1
6
1-8
7
Trip S
pee
d Lo
w
[Hz]
0.
0 Hz
Al
l s
et
-u
ps
TRU
E
-1
Ui
nt1
6
1-
9* M
o
tor
Te
mpe
rat
ur
e
1-9
0
Moto
r The
rmal Pro
tection
[4
] E
TR t
rip
1
Al
l s
et
-up
s
TR
U
E
-
Ui
nt
8
1-9
1
Moto
r Ex
te
rna
l Fa
n
[0
] No
Al
l s
et
-u
ps
TRU
E
-
Ui
nt1
6
1-9
3
Thermi
stor Source
[0] None
Al
l set-
up
s
TR
U
E
-
Ui
nt
8
5.1.3
1
-** Load /
Motor
5 Parameter Lists
VLT
®
HVAC Drive Programming Guide
5-4
MG.11.C6.22 - VLT
®
is a registered Danfoss trademark