4.9 Main Menu - PROFIdrive - Group 9
9-00 Setpoint
Range:
Function:
0
*
[0 -
65535 ]
This parameter receives cyclic reference from a
master class 2. If the control priority is set to
master class 2, the reference for the frequency
converter is taken from this parameter, whereas
the cyclic reference is ignored.
9-07 Actual Value
Range:
Function:
0
*
[0 - 65535 ] This parameter delivers the MAV for a master
class 2. The parameter is valid if the control
priority is set to master class 2.
9-15 PCD Write Configuration
Select the parameters to be assigned to PCD 3–10 of the
telegrams. The number of available PCDs depends on the
telegram type. Values in PCD 3–10 are written to the selected
parameters as data. For standard PROFIBUS telegrams, see
parameter 9-22 Telegram Selection
Option:
Function:
[0]
[302]
Minimum Reference
[303]
Maximum Reference
[312]
Catch up/slow Down Value
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[412]
Motor Speed Low Limit [Hz]
[414]
Motor Speed High Limit [Hz]
[553]
Term. 29 High Ref./Feedb.
Value
[590]
Digital & Relay Bus Control
[615]
Terminal 53 High Ref./Feedb.
Value
[625]
Terminal 54 High Ref./Feedb.
Value
[696]
Terminal 42 Output Bus
Control
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[894]
Bus Feedback 1
[1680]
Fieldbus CTW 1
[1682]
Fieldbus REF 1
[2021]
Setpoint 1
9-16 PCD Read Configuration
Select the parameters to be assigned to PCD 3–10 of the
telegrams. The number of available PCDs depends on the
telegram type. Values in PCD 3–10 contain the actual data values
of the selected parameters.
Option:
Function:
[0]
[894]
Bus Feedback 1
[1500]
Operating hours
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
[1601]
Reference [Unit]
[1602]
Reference [%]
[1603]
Status Word
[1605]
Main Actual Value [%]
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor current
[1615]
Frequency [%]
[1616]
Torque [Nm]
[1618]
Motor Thermal
[1622]
Torque [%]
[1626]
Power Filtered [kW]
[1627]
Power Filtered [hp]
[1630]
DC Link Voltage
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1638]
SL Controller State
[1639]
Control Card Temp.
[1650]
External Reference
[1652]
Feedback[Unit]
[1660]
Digital Input
[1661]
Terminal 53 Setting
[1662]
Analog Input AI53
[1663]
Terminal 54 Setting
[1664]
Analog Input AI54
[1665]
Analog Output AO42 [mA]
[1666]
Digital Output
[1667]
Pulse Input #29 [Hz]
[1671]
Relay Output [bin]
[1672]
Counter A
[1673]
Counter B
[1679]
Analog Output AO45
[1684]
Comm. Option STW
[1685]
FC Port CTW 1
[1690]
Alarm Word
[1691]
Alarm Word 2
[1692]
Warning Word
[1693]
Warning Word 2
[1694]
Ext. Status Word
Parameters
Programming Guide
MG03N202