Type designation
P11K
P15K
P18K
P22K
High/normal overload
1)
HO
NO
HO
NO
HO
NO
HO
NO
Typical shaft output [kW/(hp)]
11 (15)
15 (20)
15 (20)
18.5 (25) 18.5 (25)
22 (30)
22 (30)
30 (40)
Enclosure protection rating IP20
B3
B3
B4
B4
Enclosure protection rating IP21, IP55, IP66
B1
B1
B2
B2
Output current
Continuous (380–440 V) [A]
24
32
32
37.5
37.5
44
44
61
Intermittent (60 s overload) (380–440 V) [A]
38.4
35.2
51.2
41.3
60
48.4
70.4
67.1
Continuous (441–500 V) [A]
21
27
27
34
34
40
40
52
Intermittent (60 s overload)
(441–500 V) [A]
33.6
29.7
43.2
37.4
54.4
44
64
57.2
Continuous kVA (400 V) [kVA]
16.6
22.2
22.2
26
26
30.5
30.5
42.3
Continuous kVA (460 V) [kVA]
–
21.5
–
27.1
–
31.9
–
41.4
Maximum input current
Continuous (380–440 V) [A]
22
29
29
34
34
40
40
55
Intermittent (60 s overload)
(380–440 V) [A]
35.2
31.9
46.4
37.4
54.4
44
64
60.5
Continuous (441–500 V) [A]
19
25
25
31
31
36
36
47
Intermittent (60 s overload)
(441–500 V) [A]
30.4
27.5
40
34.1
49.6
39.6
57.6
51.7
Additional specifications
IP21, IP55, IP66 maximum cable cross-
section
2),5)
for mains, brake, and load sharing
[mm
2
] ([AWG])
16, 10, 16 (6, 8, 6)
16, 10, 16 (6, 8, 6)
35,-,-(2,-,-)
35,-,-(2,-,-)
IP21, IP55, IP66 maximum cable cross-
section
2),5)
for motor [mm
2
] ([AWG])
10, 10,- (8, 8,-)
10, 10,- (8, 8,-)
35, 25, 25 (2, 4, 4)
35, 25, 25 (2, 4, 4)
IP20 maximum cable cross-section
2),5)
for
mains, brake, motor, and load sharing [mm
2
]
([AWG])
10, 10,- (8, 8,-)
10, 10,- (8, 8,-)
35,-,-(2,-,-)
35,-,-(2,-,-)
Maximum cable cross-section
2),5)
for
disconnect [mm
2
] ([AWG])
16, 10, 10 (6, 8, 8)
Estimated power loss at rated maximum load
[W]
3)
291
392
379
465
444
525
547
739
Efficiency
4)
0.98
0.98
0.98
0.98
Table 8.5 Mains Supply 380–500 V (FC 302), 380–480 V (FC 301), P11K–P22K
Specifications
Operating Guide
MG33AT02
Danfoss A/S © 05/2018 All rights reserved.
35
8
8